Probability of Interference between LP-LDC and LBT MICS implants in a medical care facility.

Annu Int Conf IEEE Eng Med Biol Soc

Micro Systems Engineering, Lake Oswego, OR, USA.

Published: April 2008

The latest generation of medical implants incorporate RF telemetry to facilitate communication of patient data to the patient's physician. Regulatory agencies have enabled medical implant telemetry by allocating RF spectrum in the 402-405 MHz band. The first generation of regulations mandated the use of a Listen-Before-Talk (LBT) protocol. Most of these regulators, recognizing the need for expanded services, are modifying the regulations to allow a Low-Power Low-Duty-Cycle (LP-LDC) protocol as an alternative access method. Medical implant device manufacturers incorporate mitigation techniques to maintain communication in the face of expected link impairments. Designers must understand the expected operational environment and probability of interference in order to incorporate appropriate levels of such mitigation techniques. In this study the authors use the SEAMCAT-3 modeling tool to examine the probability of interference between LP-LDC and LBT medical implants in a medical care facility, where a high density of implants using either protocol can be expected. This study shows that because LP-LDC transmitters operate with very low power and low duty cycle, they can safely coexist with LBT devices, with extremely low probability of interference. Furthermore, with appropriate mitigation techniques, the probability of any harmful interference is virtually non-existent.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2007.4353903DOI Listing

Publication Analysis

Top Keywords

probability interference
16
mitigation techniques
12
interference lp-ldc
8
lp-ldc lbt
8
implants medical
8
medical care
8
care facility
8
medical implants
8
medical implant
8
medical
6

Similar Publications

Interference from a salient distractor is typically reduced when the appearance of the distractor follows either spatial or feature-based regularities. Although there is a growing body of literature on distractor location learning, the understanding of distractor feature learning remains limited. In the current study, we investigated distractor feature learning by using EEG measures.

View Article and Find Full Text PDF

Developing Topics.

Alzheimers Dement

December 2024

Multiscale Imaging and Integrative Biophysics Unit, National Institute on Aging, NIH,, Baltimore, MD, USA.

Background: Cognitive impairment with age remains undetected until it interferes daily life activity or presents dementia symptoms. In the US, 61% of dementia population is not diagnosed, which is in part due to limited sensitivity of clinical neuroimaging modalities in assessing early gray matter (GM) changes. Here we look at microstructural changes in GM using mean apparent propagator (MAP-MRI) in cognitively underperforming (CU) and healthy aging (HA) cohorts, grouped according to their cognitive performance based on the NIH Toolbox.

View Article and Find Full Text PDF

DICCR: Double-gated intervention and confounder causal reasoning for vision-language navigation.

Neural Netw

December 2024

School of Computer and Electronic Information, Guangxi University, University Road, Nanning, 530004, Guangxi, China. Electronic address:

Vision-language navigation (VLN) is a challenging task that requires agents to capture the correlation between different modalities from redundant information according to instructions, and then make sequential decisions on visual scenes and text instructions in the action space. Recent research has focused on extracting visual features and enhancing text knowledge, ignoring the potential bias in multi-modal data and the problem of spurious correlations between vision and text. Therefore, this paper studies the relationship structure between multi-modal data from the perspective of causality and weakens the potential correlation between different modalities through cross-modal causality reasoning.

View Article and Find Full Text PDF

Porous Nanoframe Based Plasmonic Structure With High-Density Hotspots for the Quantitative Detection of Gaseous Benzaldehyde.

Small

January 2025

Key Laboratory of New Energy and Rare Earth Resource Utilization of State Ethnic Affairs Commission, Key Laboratory of Photosensitive Materials & Devices of Liaoning Province, School of Physics and Materials Engineering, Dalian Minzu University, Dalian, 116600, China.

Owing to its high sensitivity, surface-enhanced Raman scattering (SERS) has immense potential for the identification of lung cancer from the variation in volatile biomarkers in the exhaled gas. However, two prevailing factors limit the application of SERS: 1) the adsorption of target molecules into SERS hotspots and 2) the detection specificity in multiple interference environments. To improve the density of the SERS hotspots, 3D Au@Ag-Au particles are prepared in a porous nanoframes (PPFs) based plasmonic structure, which facilitated a richer local electromagnetic field distribution among the Au nanocubic (NC) cores, Au-Ag porous nanoframes, and Au nanoparticles, thereby promoting the adsorption probability of gaseous aldehydes into the hotspots.

View Article and Find Full Text PDF

Background: Depression commonly arises among adolescents who have experienced long-standing psychosocial difficulties, especially those facing chronic illnesses such as sickle cell anemia (SCA). SCA is a global health concern, and Tanzania is one of the countries with a high incidence, estimated at 8,000-11,000 births per year. This study aims to assess the magnitude and factors associated with depression among adolescents with SCA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!