Guidelines for calibration and drift compensation of a wearable device with rate-gyroscopes and accelerometers.

Annu Int Conf IEEE Eng Med Biol Soc

Dipartimento di Tecnologie e Salute, Istituto Superiore di Sanità, via Regina Elena 299, 00161 Roma.

Published: March 2008

The technical note describes a methodology for the calibration and the drift compensation of a device with accelerometers and rate-gyroscopes. The methodology is based on a step-wise-motor approach and a simulation environment with the device simulation model for optimisation of the calibration parameters. The validation on a wide range of locomotion tasks performed by 30 subjects with some unbalance problems showed the feasibility of the methodology. In particular, a correlation was found between simulated and actual data (0.15 degrees in maximal value). Results also showed that the drift compensation procedure significantly improved the performances of the device.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2007.4352796DOI Listing

Publication Analysis

Top Keywords

drift compensation
12
calibration drift
8
guidelines calibration
4
compensation wearable
4
device
4
wearable device
4
device rate-gyroscopes
4
rate-gyroscopes accelerometers
4
accelerometers technical
4
technical note
4

Similar Publications

A High-Precision Temperature Compensation Method for TMR Weak Current Sensors Based on FPGA.

Micromachines (Basel)

November 2024

State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China.

Tunnel magnetoresistance (TMR) sensors, known for their high sensitivity, efficiency, and compact size, are ideal for detecting weak currents, particularly leakage currents in smart grids. However, temperature variations can negatively impact their accuracy. This work investigates the effects of temperature variations on measurement accuracy.

View Article and Find Full Text PDF

Cyclic Voltarefractometry of Single TiO Nanoparticles in Large Ensembles in Nonaqueous Electrolyte.

Anal Chem

January 2025

Nanobiotechnology Department of the Institute of Biotechnology, Brandenburg University of Technology Cottbus-Senftenberg, Universitaetsplatz 1, Senftenberg 01968, Brandenburg, Germany.

Single nanoparticle (NP) cyclic voltarefractometry (CVR), realized as wide-field surface plasmon resonance microscopy (SPRM) in combination with potential cycling, has been proposed and applied to the in situ study of TiO NPs. Electrochemical activity of TiO is mainly observed outside the electrochemical stability window of water. Therefore, the response of individual anatase (a-TiO) and rutile (r-TiO) NPs adsorbed on a gold layer was studied in 0.

View Article and Find Full Text PDF

This paper presents a novel adaptive fault-tolerant control (AFTC) framework for systems with piezoelectric sensor patches, specifically targeting sensor faults and external disturbances. The proposed method ensures robust control of cantilever thick plates by integrating adaptive estimation to simultaneously handle sensor faults and system uncertainties, maintaining stability despite issues like drift, bias, loss of accuracy, and effectiveness. Unlike traditional approaches that address sensor faults individually, our method provides a comprehensive solution backed by Lyapunov-based stability analysis, demonstrating uniform ultimate boundedness under various fault conditions.

View Article and Find Full Text PDF

A differential microelectromechanical system (MEMS) quartz resonant accelerometer with a novel oscillating readout circuit is proposed. The phase noise in a piezoelectric quartz resonant accelerometer has been systematically investigated. A high-performance front-end is used to extract the motional charge from a piezoelectric quartz resonator for the first time.

View Article and Find Full Text PDF

Magnetic circularly polarized luminescence (MCPL) spectroscopy is widely used to evaluate the luminescence dissymmetry factor (g) for compounds. However, even for the same instrument and operating conditions, the measured g is affected by errors associated with sources such as baseline drift and spectral noise, and so the range of variation of g must be considered when comparing values, which requires multiple measurements for the same sample. Also, because many samples undergo photodegradation under excitation light, it is difficult to accumulate and average spectra for samples with weak MCPL signals to improve the signal-to-noise ratio.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!