Nanostructured thin films for the development of piezoelectric immunosensors.

Annu Int Conf IEEE Eng Med Biol Soc

Department of Communication, Computer and System Sciences, University of Genova, Italy.

Published: March 2008

Monoclonal antibodies were immobilized onto the surface of quartz crystals for the development of piezoelectric biosensors by means of the Layer by Layer self assembly technique (LBL). Specifically, the immobilization of immunoglobulins specific to the human cytokine Transforming Growth Factor Beta1 and to taxol was investigated. To this purpose multilayered ultra-thin films composed by precursor layers of cationic poly(dimethyldiallylammonium) chloride and anionic poly(styrenesulfonate) followed by a monolayer of antibodies were assembled by LBL. A quartz crystal microbalance was used to monitor and optimize the assembly process and to test the immunological activity of the deposited antibody molecules. Atomic force microscopy was used to characterize the surface roughness of the multilayers before and after the deposition of the immunoglobulins. The results confirmed the successful deposition of the proposed immunosensors and demonstrated their high potential for the measurement of analytes of clinical interest.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2007.4352774DOI Listing

Publication Analysis

Top Keywords

development piezoelectric
8
nanostructured thin
4
thin films
4
films development
4
piezoelectric immunosensors
4
immunosensors monoclonal
4
monoclonal antibodies
4
antibodies immobilized
4
immobilized surface
4
surface quartz
4

Similar Publications

Neural-electronic interfaces through delivering electroceuticals to lesions and modulating pathological endogenous electrical environments offer exciting opportunities to treat drug-refractory neurological disorders. Such an interface should ideally be compatible with the neural tissue and aggressive biofluid environment. Unfortunately, no interface specifically designed for the biofluid environments is available so far; instead, simply stacking an encapsulation layer on silicon-based substrates makes them susceptible to biofluid leakage, device malfunction, and foreign-body reactions.

View Article and Find Full Text PDF

Cancer cells produce extracellular vesicles (EVs) coated with an anionic sugar polymer, hyaluronan (HA), in the extracellular matrix. Hyaluronan is an established cancer biomarker in several cancer types. In this work, we thoroughly investigated the electrical properties of HA-coated EVs using advanced scanning probe microscopy (SPM) based nanoelectrical modes, which include EFM (electrostatic force microscopy), KPFM (Kelvin probe force microscopy), PFM (piezoresponse force microscopy) and C-AFM (conductive atomic force microscopy).

View Article and Find Full Text PDF

Flexible micromachined ultrasound transducers (MUTs) for biomedical applications.

Microsyst Nanoeng

January 2025

Department of Electrical Engineering (ESAT-MNS), KU Leuven, Belgium.

The use of bulk piezoelectric transducer arrays in medical imaging is a well-established technology that operates based on thickness mode piezoelectric vibration. Meanwhile, advancements in fabrication techniques have led to the emergence of micromachined alternatives, namely, piezoelectric micromachined ultrasound transducer (PMUT) and capacitive micromachined ultrasound transducer (CMUT). These devices operate in flexural mode using piezoelectric thin films and electrostatic forces, respectively.

View Article and Find Full Text PDF

Enhanced piezoelectric sensor to distinguish real-time arrhythmia for predicting heart failure.

Biosens Bioelectron

January 2025

Institute of Biomedical Engineering, College of Medicine, Southwest Jiaotong University, Chengdu, 610031, Sichuan, PR China; Key Laboratory of Advanced Technologies of Materials Ministry of Education, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu, 610031, PR China. Electronic address:

Monitoring cardiac rhythm is crucial for diagnosis of heart failure. However, the deficient sensitivity of polyvinylidene fluoride (PVDF) sensors impede their application in monitoring of cardiac rhythm due to the limited piezoelectricity. Here, doping of CoFeO and aligning fibers were jointly adopted to enhance the piezoelectricity of PVDF, attributed to the transformation of α-PVDF to β-PVDF from 51.

View Article and Find Full Text PDF

Recent Advances in Self-Powered Sensors Based on Ionic Hydrogels.

Research (Wash D C)

January 2025

School of Physics & Wuhan National Laboratory for Optoelectronics (WNLO), Huazhong University of Science and Technology (HUST), Wuhan 430074, China.

After years of research and development, flexible sensors are gradually evolving from the traditional "electronic" paradigm to the "ionic" dimension. Smart flexible sensors derived from the concept of ion transport are gradually emerging in the flexible electronics. In particular, ionic hydrogels have increasingly become the focus of research on flexible sensors as a result of their tunable conductivity, flexibility, biocompatibility, and self-healable capabilities.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!