A simple and efficient algorithm with a coarse to fine approach for arterial beat pulse detection.

Annu Int Conf IEEE Eng Med Biol Soc

Laboratoire d'Optronique, Ecole Nationale Supérieure de Sciences Appliquées et de Technologie ENSSAT, 6 rue de Kérampont BP 80518 22305 Lannion, France.

Published: March 2008

This paper presents a simple algorithm for arterial beat pulse detection. It consists in a coarse to fine approach : the first step is performed with a lifting Haar wavelet transform with thresholding and provides search intervals, the second step is to localize the beat pulse in the original signal within these areas. Thanks to online available database, the performance of this algorithm can be compared to others and its ability to detect peaks is sufficient considering its low amount of calculation.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2007.4352279DOI Listing

Publication Analysis

Top Keywords

beat pulse
12
coarse fine
8
fine approach
8
arterial beat
8
pulse detection
8
simple efficient
4
efficient algorithm
4
algorithm coarse
4
approach arterial
4
detection paper
4

Similar Publications

Background: Binaural beat is created by presenting two different pure-tone sine waves with less than a 30Hz difference dichotically. In dental settings, children listening to familiar music during treatments gain control over the anxiety caused by tools like the airotor or syringe, creating a comforting, familiar environment.

Aim: To evaluate and compare anxiety level during restorative treatment using No Music, Music of choice and Binaural Auditory Beats as Audio distraction behaviour guidance technique in children aged 6-12 years.

View Article and Find Full Text PDF

Polymer-Layered Optical Wearable (PLOW) for Healthcare Applications: Temperature and Stretching Monitoring.

ACS Appl Mater Interfaces

January 2025

Nanophotonics and Plasmonics Laboratory, School of Basic Sciences, Indian Institute of Technology Bhubaneswar, Bhubaneswar, Odisha 752050, India.

Thermal and stretching characteristics are crucial variables in healthcare, robotics, and human-machine interaction applications. Here, we present a single-mode fiber-based, balloon-shaped, single- and dual polymer-layered optical wearable (PLOW) system that can sense both temperature and stretching. These two types of PLOWs are compared in terms of their detection performance across all criteria.

View Article and Find Full Text PDF

Joint Analysis of Cardiovascular Control and Shear Wave Elastography to Determine Carotid Plaque Vulnerability.

J Clin Med

January 2025

Operative Unit of Vascular Surgery, IRCCS Policlinico San Donato, 20097 San Donato Milanese, Italy.

: Carotid artery stenosis (CAS) is one of the main causes of stroke, and the vulnerability of plaque has been proved to be a determinant. A joint analysis of shear wave elastography, a radiofrequency echo-based wall tracking technique for arterial stiffness evaluation, and of autonomic and baroreflex function is proposed to noninvasively, preoperatively assess plaque vulnerability in asymptomatic CAS patients scheduled for carotid endarterectomy. : Elastographic markers of arterial stiffness were derived preoperatively in 78 CAS patients (age: 74.

View Article and Find Full Text PDF

Attenuated cardiac autonomic function in patients with long-COVID with impaired orthostatic hemodynamics.

Clin Auton Res

January 2025

Department of Cardiac Sciences, Libin Cardiovascular Institute, University of Calgary, GAC70 HRIC Building, 3280 Hospital Dr NW, Calgary, AB, T2N 4Z6, Canada.

Purpose: Long-coronavirus disease (long-COVID) is associated with initial orthostatic hypotension and postural orthostatic tachycardia syndrome. Whether altered autonomic tone underlies these abnormalities is unknown. We compared autonomic function between patients with long-COVID and healthy controls, and within patients with long-COVID with different orthostatic hemodynamic phenotypes.

View Article and Find Full Text PDF

Neuromodulation comes into focus as a non-pharmacological therapy with the vagus nerve as modulation target. The auricular vagus nerve stimulation (aVNS) has emerged to treat chronic diseases while re-establishing the sympathovagal balance and activating parasympathetic anti-inflammatory pathways. aVNS leads still to over and under-stimulation and is limited in therapeutic efficiency.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?