AI Article Synopsis

Article Abstract

Our aim was to validate the clinical feasibility of assessment of the area of the aortic valve orifice (AVA) by real time three-dimensional echocardiography (RT3DE) in biplane mode by planimetry and to compare it with the echo-Doppler methods more commonly used to evaluate valvular aortic stenosis (AS).RT3DE in biplane mode is a novel technique that allows operators to visualize the aortic valve orifice anatomy in any desired plane orientation. Its usefulness and accuracy have not previously been established. Using this technique, we studied a series of patients with AS and compared the results with those obtained by two-dimensional transesophageal echocardiography (TEE) planimetry and two-dimensional transthoracic echocardiography using the continuity equation (TTE-CE). RT3DE planimetries in biplane mode were measured by two independent observers. Bland-Altman analysis was used to compare these two methods.Forty-one patients with AS were enrolled in the study (15 women, 26 men, mean age 73.5 +/- 8.2 years). RT3DE planimetry was feasible in 92.7%. Average AVA determined by TTE-CE was 0.76 +/- 0.20 cm, by TEE planimetry 0.73 +/- 0.1 cm, and by RT3DE planimetry 0.76 +/- 0.20 cm(2). The average differences in AVA were-0.001 +/- 0.254 cm(2) and 0.03 +/- 0.155 cm(2) (RT3DE/TEE). The correlation coefficient for AVA (RT3DE/TTE-CE) was 0.82 and for AVA (RT3DE/TEE) it was 0.94, P < 0.0001. No significant intra- and interobserver variability was observed. In conclusion, RT3DE in biplane mode provides a feasible and reproducible method for measuring the area of the aortic valve orifice in aortic stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8175.2007.00526.xDOI Listing

Publication Analysis

Top Keywords

biplane mode
20
aortic valve
16
aortic stenosis
12
valve orifice
12
real time
8
time three-dimensional
8
three-dimensional echocardiography
8
two-dimensional transthoracic
8
transesophageal echocardiography
8
area aortic
8

Similar Publications

Transcatheter Aspiration of Tricuspid Vegetation.

JACC Case Rep

December 2024

Jesselson Integrated Heart Center, The Eisenberg R&D Authority, Shaare Zedek Medical Center, Faculty of Medicine, The Hebrew University of Jerusalem, Jerusalem, Israel.

Objective: This study sought to present the endovascular approach of transcatheter aspiration using the FlowTriever (Inari Medical) aspiration system for high surgical risk patients with right-sided infective endocarditis.

Key Steps: General anesthesia and transesophageal echocardiogram guidance; ultrasonography-guided femoral vein access, preclosure sutures, and insertion of a 24-F sheath; insertion of straight 24-F aspiration cannula over a stiff wire, parked in the superior vena cava; introduction of a 20-F curved cannula inside the 24-F cannula to create a telescopic assembly; accurate positioning using the right ventricle inflow/outflow projection in biplane mode; adjustment of the curved cannula radius by sliding the inner cannula in and out inside the mother cannula; manual aspiration of the vegetation; Postaspiration transesophageal echocardiogram assessment.

Potential Pitfalls: Avoid leaflet and annular injury and account for potential embolization.

View Article and Find Full Text PDF

Left Atrial Size and Strain in Hypertensive Children Compared to Age-, Sex-, and Race/Ethnicity-Matched Controls.

Pediatr Cardiol

November 2024

Division of Cardiology, Department of Pediatrics, Children's Hospital of Philadelphia, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA, USA.

Left atrial (LA) volume and peak longitudinal strain (LA strain) are indicators of left ventricular (LV) diastolic function in adults, but little is known about LA volume and strain in pediatric patients with hypertension (HTN). We evaluated LA volume and strain in pediatric cases with HTN compared to age-, sex-, and race/ethnicity-matched controls. This was a retrospective matched case-control study of patients who presented to the HTN clinic at CHOP from 12/2011 to 9/2018.

View Article and Find Full Text PDF

Background: It is reasonable to introduce a microaxial flow pump (Impella) before coronary angiography and left ventriculography (LVG) to prioritize treating tissue hypoperfusion in patients with takotsubo syndrome (TTS) and refractory cardiogenic shock. However, left ventricular (LV) unloading by an Impella device might prevent contrast media from filling the left ventricle, making it difficult to evaluate LV wall motion abnormalities during LVG.

Case Summary: A 76-year-old female with ST elevations in I, II, aVL, and V1-6 on electrocardiography and severe LV dysfunction on echocardiography immediately received circulatory support with Impella CP to treat refractory cardiogenic shock.

View Article and Find Full Text PDF

Background: Cardiac magnetic resonance imaging (cMRI) is considered the gold standard for the assessment of left ventricular (LV) systolic function. However, discrepancies have been reported in the literature between LV volumes assessed by transthoracic echocardiography (TTE) and cMRI. The objective of this study was to analyze the differences in LV volumes between different echocardiographic techniques and cMRI.

View Article and Find Full Text PDF

Which left atrial volume measurement should we use in the neonatal intensive care?

Early Hum Dev

April 2024

John Hunter Children's Hospital, Department of Neonatology, Newcastle, NSW, Australia; University of Newcastle, Newcastle, NSW, Australia.

Background: Increased left atrial volume (LAV) is a marker of cardiovascular risk. Echocardiography standards to assess LAV in adults and children are the biplane area-length method (AL) and method of disks (MOD). LAV in neonatology is usually derived as M-mode ratio between the LA and the Aorta (LAAo).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!