A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Evaluation of skull thickness and insertion torque at the halo pin insertion areas in the elderly: a cadaveric study. | LitMetric

Background Context: The halo skeletal fixator provides the most rigid type of immobilization of all the orthoses that stabilize the cervical spine. Sometimes with older patients (>70 years old), the pin penetrates the cortical and cancellous bone of the skull and enters the intracranial space, which can result in serious complications such as brain injury, infection, hematoma, and loss of cerebrospinal fluid from the subarachnoid space. Currently, there is a lack of relevant literature that examines these concerns.

Purpose: To evaluate the thickness of the outer table, diploe, and inner table at the anterolateral and posterolateral pin insertion areas of the skull in elderly cadavers by using computed tomography (CT) scans. In addition, insertion torques at the four standard pin insertion areas was determined by applying halo pins at incremental torque in an effort to suggest safe torque levels for the anterolateral and posterolateral pins.

Study Design/setting: A human cadaveric anatomical and biomechanical study relating to thickness and insertion torques at standard pin areas in the elderly.

Patient Sample: Twenty-one elderly cadaveric skull specimens.

Outcome Measures: Thickness of cortices (tables) and diploe of skull and insertion torque at halo pin insertion areas.

Methods: Aquarius Image software at the CT scanner's TeraRecon Aquarius Workstation was used to make the necessary skull thickness measurements at the pin insertion areas. Six, 8, 12, 18, and 36 inch lb of torque were used to determine penetration of the pins through the inner table at each of the four locations (two anterolateral and two posterolateral).

Results: The mean anterolateral thickness was 7.36+/-1.57 mm. The average thickness of the outer table, diploe, and inner table were 2.24+/-0.44 mm, 1.52+/-0.41 mm, and 3.59+/-1.70 mm, respectively. The mean posterolateral thickness was 9.47+/-1.12 mm. The average thickness of the outer table, diploe, and inner table were 4.32+/-0.92 mm, 1.88+/-0.35 mm, and 3.27+/-1.21 mm, respectively. No pin penetration was seen at the traditional 8 inch lb of insertion torque in both the anterolateral and posterolateral pin insertion areas. Eighteen inch lb of torque resulted in penetration in 90.48% (19/21) and in 85.71% (18/21) of specimens in the left anterolateral and right anterolateral pin insertion areas, respectively. No penetration was seen even at 36 inch lb of torque in 80.95% (17/21) of the cadavers in both the left and right posterolateral pin insertion areas.

Conclusions: The current study supported previous research that 8 inch lb of torque is safe for application of halo pins in the elderly. The posterolateral skull is thicker and stronger than the anterolateral skull. The safe maximum torque is 8 inch lb for anterolateral pin insertion area and 18 inch lb for the posterolateral pin insertion area.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.spinee.2006.09.007DOI Listing

Publication Analysis

Top Keywords

pin insertion
40
insertion areas
24
inner table
16
posterolateral pin
16
inch torque
16
insertion
15
pin
13
insertion torque
12
thickness outer
12
outer table
12

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!