A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Pilot test of prenatal surveillance for birth defects in South Texas. | LitMetric

Pilot test of prenatal surveillance for birth defects in South Texas.

Birth Defects Res A Clin Mol Teratol

Texas Center for Birth Defects Research and Prevention, Birth Defects Epidemiology and Surveillance Branch, Texas Department of State Health Services, Austin, Texas, USA.

Published: November 2007

Background: The Texas Birth Defects Registry (TBDR) does not access prenatal diagnostic facilities to ascertain cases. Objectives of the study were to determine how many cases may be missing from the registry as a result, and to assess the feasibility and utility of prenatal surveillance for birth defects, through a pilot test in one region of Texas.

Methods: A trained abstractor reviewed medical records of all patients with abnormal ultrasound findings during 2004 in all prenatal diagnostic facilities in Texas Health Region 11 (n = 6 facilities). When birth defects were prenatally detected, demographic and diagnostic data were abstracted. Prenatal abstractions were matched to cases in the TBDR. Those that did not match to registry cases were matched to vital records to determine where and when the pregnancy ended; delivery hospital medical records were reviewed for these cases.

Results: Approximately 760 patient charts were reviewed at prenatal diagnostic facilities and 365 were abstracted. Of these, 165 (45%) matched to cases in the TBDR. Delivery medical records were located and reviewed for 177 prenatal abstractions, with 170 (47%) indicating at delivery no defects monitored by the registry. Delivery records for one (0.3%) prenatal abstraction were not found by the hospital. Date and place of delivery were unknown for 22 (6%) prenatal abstractions. Only eight additional infants and fetuses (one twin pair) eligible for the registry were identified.

Conclusions: For Texas Health Service Region 11, it is not necessary to conduct surveillance in prenatal diagnostic facilities, and to do so would be very labor-intensive.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bdra.20405DOI Listing

Publication Analysis

Top Keywords

birth defects
16
prenatal diagnostic
16
diagnostic facilities
16
medical records
12
prenatal abstractions
12
prenatal
10
pilot test
8
prenatal surveillance
8
surveillance birth
8
texas health
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!