A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A fully automated 2-D LC-MS method utilizing online continuous pH and RP gradients for global proteome analysis. | LitMetric

The conventional 2-D LC-MS/MS setup for global proteome analysis was based on online and offline salt gradients (step and continuous) using strong-cation-exchange chromatography in conjunction with RP chromatography and MS. The use of the online system with step salt elution had the possibility of resulting in peptide overlapping across fractions. The offline mode had the option to operate with continuous salt gradient to decrease peak overlap, but exhibited decreased robustness, lower reproducibility, and sample loss during the process. Due to the extensive washing requirement between the chromatography steps, online continuous gradient was not an option for salt elution. In this report, a fully automated, online, and continuous gradient (pH continuous online gradient, pCOG) 2-D LC-MS/MS system is introduced that provided excellent separation and identification power. The pH gradient-based elution provided more basic peptides than that of salt-based elution. Fraction overlap was significantly minimized by combining pH and continuous gradient elutions. This latter approach also increased sequence coverage and the concomitant confidence level in protein identification. The salt and pH elution-based 2-D LC-MS/MS approaches were compared by analyzing the mouse liver proteome.

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.200700463DOI Listing

Publication Analysis

Top Keywords

online continuous
12
2-d lc-ms/ms
12
continuous gradient
12
fully automated
8
global proteome
8
proteome analysis
8
salt elution
8
continuous
7
online
6
salt
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!