Objectives: To determine in the laboratory whether there are or are not differences between individual geometrical designs of intramedullary and extramedullary devices used for the fixation of extraarticular proximal tibial fractures.
Methods: Five devices were tested: a newly developed Proximal Tibia Nail (PTN), conventional double-plate osteosynthesis (DPO), the Less Invasive Stabilization System (LISS), an augmented Unreamed Tibial Nail with a T-stabilization-plate (UTN + TSP), and an external fixator (ExFix). A 10-mm defect osteotomy was performed on paired human tibiae, and the proximal and distal ends were potted in polymethylmethacrylate cement (PMMA). Each pair of bones was randomly stabilized with the new PTN in 1 tibia (Groups PTN1 through PTN4) and in 1 of the 4 comparative implants in the corresponding contralateral bone. A biomechanical test of the bone implant construct was then performed with a vertical axial force of 350, 600, and 900 N, a bending moment of 6 Nm and a bidirectional rotational strain of 8 Nm. Displacement of bone fragments was measured and depicted as a force-displacement diagram.
Results: For axial loading, significant differences were seen between the PTN 2 group compared to the LISS group (P = 0.016) and the PTN 4 group compared to the ExFix group (P = 0.016). No statistically significant differences were seen for the PTN 1 group compared to the DPO group (P = 0.125) and the PTN 3 group compared to the UTN + TSP group (P = 0.453). The bending stiffness of the PTN 1-4 groups was not significantly different from any of the 4 alternative implants. There was comparable torsional stiffness in all implant groups except for the UTN + TSP group, which was less stable and significantly different from the PTN 3 group (P = 0.016).
Conclusions: Given the parameters of this investigation, the new PTN would theoretically provide the same mechanical stability as the DPO in axial loading. Higher stability in axial loading may be present when compared to the LISS or the ExFix. Further clinical investigation of this implant will determine its usefulness among proximal tibial fixation devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0b013e31815aba5e | DOI Listing |
Medicina (Kaunas)
December 2024
Department of Endodontics, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey.
: The access cavity design and instrumentation system could affect the remaining root canal obturation materials in root canal retreatment. This study aimed to evaluate the efficiency of two different multi-file systems in removing obturation materials with two different access cavities utilizing micro-CT scanning. : Conservative access cavity (CAC) preparation was performed for 80 mandibular premolars.
View Article and Find Full Text PDFFront Immunol
January 2025
Department of Urology, The Second People's Hospital of Meishan City, Meishan, Sichuan, China.
Background: Prostate cancer (PCa) is a multifactorial and heterogeneous disease, ranking among the most prevalent malignancies in men. In 2020, there were 1,414,259 new cases of PCa worldwide, accounting for 7.3% of all malignant tumors.
View Article and Find Full Text PDFInt J Surg Case Rep
January 2025
Neurosurgical Unit, National Hospital of Sri Lanka, Colombo, Sri Lanka.
Introduction: Schwannoma is a type of slow growing benign nerve sheath tumor arising from Schwann cells. Peripherally, they are found in association with the ulnar, sciatic and posterior tibial nerves. Peripheral schwannomas, neurofibromas and malignant PNSTs are collectively grouped as peripheral nerve sheath tumors.
View Article and Find Full Text PDFJ Chem Phys
December 2024
Marine Engineering College, Dalian Maritime University, Dalian 116026, China.
Strategies for controlling the size of metal species using zeolites and their catalytic behavior in industrially relevant processes have attracted widespread attention, but the effect of H2O and CO2 on the catalytic performance of zeolite-based metal catalysts remains obscure. This study investigated the influence of H2O and CO2 on CO oxidation over zeolite-based metal catalysts, along with the precise control of active sites through the regulation of Lewis acidity. It was found that the presence of H2O enhanced CO oxidation and alleviated the inhibitory effect of CO2.
View Article and Find Full Text PDFRestor Dent Endod
November 2024
Department of Endodontics, Faculty of Dentistry, Cairo University, Cairo, Egypt.
Objectives: This study evaluated the effect of ProTaper Next (PTN), ProTaper Universal Retreatment (PTR) and hybrid instrumentation (HI) for canal filling removal on the fracture resistance (FR), mode of failure (MoF), and filling removal time.
Materials And Methods: Ninety-six, mandibular premolars were decoronated and randomly divided into 6 groups ( = 16), as follows: sound (S), untreated canals; prepared teeth (P), canals only prepared to ProTaper Universal finishing instrument (F4); endodontically-treated (ET), prepared and obturated canals using the single-cone technique; and groups PTN, PTR, and HI where filling was removed using PTN, PTR, or HI respectively. FR under vertical loading; MoF and time were assessed.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!