Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Reliable detection of myocardial scarring in nonischemic cardiomyopathy is time-consuming using techniques that require determination of optimal inversion time. Therefore we evaluated an inversion-time-insensitive approach using a fast phase-sensitive inversion recovery (PSIR) sequence to detect and quantify late gadolinium enhancement (LGE).
Patients And Methods: Twenty patients (mean age 40 years, 9 females) with nonischemic cardiomyopathy and evidence of LGE were evaluated. After administration of 0.2 mmol/kg gadolinium diethylene triamine pentaacetic acid, a segmented 2D inversion recovery turbo fast low-angle shot gradient echo recall (GRE) sequence [echo time (TE) 4.3 milliseconds, repetition time (TR) 750 milliseconds, alpha 30 degrees , voxel size 1.7 x 1.3 x 8-10 mm] was obtained and served as the standard of reference. Second, a fast multislice single-shot 2D PSIR sequence (TE 1.1 millisecond, TR 700 milliseconds, alpha 40 degrees , voxel size 2.5 x 1.7 x 8-10 mm) was acquired in the same slice positions. The PSIR(IR) images were used to analyze LGE. Altogether 53 short-axis slices with LGE were evaluated. Contrast-to-noise ratio and area of LGE were calculated and compared by 2 experienced readers. Image quality and confidence level for identification of LGE were rated on 5-point scales. Interobserver variability was evaluated in 10 patients.
Results: All images were interpretable. Imaging time was reduced from 385 +/- 127 seconds to 20 +/- 3 seconds (P < 0.001). Contrast-to-noise ratio was 8.29 for PSIRmag and 12.07 for the conventional GRE images (P < 0.001). The mean area of LGE was 1.01 +/- 0.62 cm(2) for the GRE sequence and 1.10 +/- 0.62 cm(2) for PSIR(IR) (P = NS). The general linear model showed no interaction between the results and no significant difference of the mean (r = 0.09, mean difference 0.09 cm(2)). The overall interobserver variability of PSIR(IR) and GRE was excellent, with Pearson's correlation coefficients of r = 0.96 for PSIR(IR) and r = 0.98 for GRE. PSIR(IR) and conventional GRE were comparable in terms of image quality and confidence level (image quality: 1.6 +/- 0.67 vs. 1.5 +/- 0.93, P = NS; confidence level: 1.4 +/- 0.84 vs. 1.3 +/- 0.5; P = NS).
Conclusions: Fast PSIR sequences enable accurate detection and quantification of LGE in nonischemic cardiomyopathies. The examination time can be significantly shortened using the single-shot approach of the PSIR technique.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/RLI.0b013e3180661a95 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!