Background: Transluminal replacement of a displaced peritoneal catheter (TRC) using a metal guidewire is a noninvasive treatment of catheter displacement with acute malfunction. The "alpha-replacer" is a special guidewire developed specifically for TRC. This wire is usually flexible but becomes harder if coiled in the hand. Application of this unique guidewire might improve the effectiveness of TRC.

Methods: TRC using an alpha-replacer was performed in 10 cases for urgent correction of peritoneal catheter displacement. All patients had received a double cuffed, straight-end swan-neck catheter.

Results: The primary success rate of TRC using the alpha-replacer was 90% (9 of 10 cases). No patients developed complications such as injury of the peritoneum or abdominal organs. Relapse of catheter displacement was observed in 2 cases (20%) within 1 week, requiring surgical intervention to prevent relapse.

Conclusion: TRC using the alpha-replacer as described herein offers effective and safe treatment of peritoneal catheter displacement.

Download full-text PDF

Source

Publication Analysis

Top Keywords

peritoneal catheter
16
catheter displacement
16
trc alpha-replacer
12
transluminal replacement
8
replacement displaced
8
displaced peritoneal
8
catheter
6
trc
5
peritoneal
4
catheter special
4

Similar Publications

Background: Nursing sensitive indicators are a way of measuring aspects of patient care that are most affected by the actions of the nurse. Despite the existence of nursing sensitive indicators, these are largely not suitable to measure peritoneal dialysis nursing practice.

Objective: This project aimed to co-develop a set of peritoneal dialysis nursing-sensitive indicators.

View Article and Find Full Text PDF

Background: Intrabdominal pressure (IAP) is an important parameter. Elevated IAP can reduce visceral perfusion, lead to intraabdominal hypertension, and result in life-threatening abdominal compartment syndrome. While ingestible capsular devices have been used for various abdominal diagnoses, their application in continuous IAP monitoring remains unproven.

View Article and Find Full Text PDF

The incidence of inflow and drain pain and associated risk factors for patients on peritoneal dialysis.

BMC Nephrol

January 2025

Department of Nephrology, The First Affiliated Hospital, Sun Yat-sen University, 58th, Zhongshan Road II, Guangzhou, 510080, Guangdong, PR China.

Background: The high prevalence and prolonged duration of inflow pain and drain pain experienced by peritoneal dialysis (PD) patients following PD catheter implantation impact their quality of life. However, there is limited data on the frequency and predisposing factors of these pains in the Chinese population undergoing peritoneal dialysis.

Methods: This study encompassed individuals who underwent peritoneal dialysis catheter implantation at our institution from September 1, 2023, to March 31, 2024.

View Article and Find Full Text PDF

Objective: Peritoneal dialysis(PD)-associated peritonitis is a common and major complication of PD and the most common cause of technical failure of PD. The presence of bacterial biofilm may be an important factor leading to refractory or recurrence of peritonitis. To investigate the formation and characteristics of bacterial biofilms on PD catheters after peritonitis-associated catheter removal.

View Article and Find Full Text PDF

Introduction: The Retzius-sparing technique for prostate cancer has shown favorable continence recovery outcomes. Magnetic resonance imaging after Retzius-sparing showed that the bladder anterior wall is widely connected to the abdominal wall, which contributes to urinary continence. We aimed to evaluate whether the Peritoneal Fixation technique, which involves suturing the anterior bladder wall onto the abdominal wall above the pubic bone, contributes to the recovery of urinary continence.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!