A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accelerated solid-phase dynamic extraction of toluene from air. | LitMetric

Accelerated solid-phase dynamic extraction of toluene from air.

J Chromatogr A

Research Group EnVOC, Department of Organic Chemistry, Faculty of Bioscience Engineering, Ghent University, Coupure Links 653, B-9000 Ghent, Belgium.

Published: December 2007

Solid-phase dynamic extraction (SPDE) belongs to the most innovative sample preparation and enrichment techniques. However, there is still a lack of knowledge on the fundamentals of SPDE and its applicability in the field of environmental monitoring. A homemade sampling device is constructed to make a detailed study of SPDE kinetics for toluene extraction. It proved that at least 50 aspirating and dispensing cycles were necessary to obtain toluene equilibration between gas and coating phase. A mechanistic model is proposed to explain that in every dispensing step during SPDE, significant losses of retained analytes (up to 48%) occur due to desorption processes. A new accelerated solid-phase dynamic extraction procedure (ASPDE) has been developed that avoids dispensing stages during extraction. The resulting extraction time proves to be 1.7 min, being a reduction by a factor of 37 compared with the SPDE extraction time. ASPDE proved to have high potential in ambient/indoor air monitoring. The limit of detection for toluene was determined to be 56 ppb(v), i.e. a factor of respectively, 6 and 35 lower than obtained with SPME and conventional headspace sampling with gas syringe.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2007.10.043DOI Listing

Publication Analysis

Top Keywords

solid-phase dynamic
12
dynamic extraction
12
accelerated solid-phase
8
extraction time
8
extraction
7
spde
5
toluene
4
extraction toluene
4
toluene air
4
air solid-phase
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!