The interaction between a cationic polyelectrolyte, chitosan, and an exogenous bovine lung extract surfactant (BLES) was studied using dynamic compression/expansion cycles of dilute BLES preparations in a Constrained Sessile Drop (CSD) device equipped with an environmental chamber conditioned at 37 degrees C and 100% R.H. air. Under these conditions, dilute BLES preparations tend to produce variable and relatively high minimum surface tensions. Upon addition of "low" chitosan to BLES ratios, the minimum surface tension of BLES-chitosan preparations were consistently low (i.e. <5 mJ/m2), and the resulting surfactant monolayers (adsorbed at the air-water interface) were highly elastic and stable. However, the use of "high" chitosan to BLES ratios induced the collapse of the surfactant monolayer at high minimum surface tensions (i.e. >15 mJ/m2). The zeta potential of the lung surfactant aggregates in the subphase suggests that chitosan binds to the anionic lipids (phosphatidyl glycerols) in BLES, and that this binding is ultimately responsible for the changes in the surface activity (elasticity and stability) of these surfactant-polyelectrolyte mixtures. Furthermore the transition from "low" to "high" chitosan to BLES ratios correlates with the flocculation and de-flocculation of surfactant aggregates in the subphase. It is proposed that the aggregation/segregation of "patches" of anionic lipids in the surfactant monolayer produced at different chitosan to BLES ratios explains the enhancing/inhibitory effects of chitosan. These observations highlight the importance of electrostatic interactions in lung surfactant systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bbamem.2007.10.003 | DOI Listing |
ACS Appl Bio Mater
April 2024
National University of Science and Technology MISIS, Leninskiy pr. 4, Moscow 119049, Russian Federation.
Local recurrence after surgical and therapeutic treatment remains a significant clinical problem in oncology. Recurrence may be due to imperfections in existing therapies, particularly chemotherapy. To improve antitumor activity and prevent local cancer recurrence while keeping toxicity at acceptable levels, we have developed and demonstrated a biodegradable local chemotherapy platform that provides controlled and prolonged drug release.
View Article and Find Full Text PDFBiochim Biophys Acta
May 2010
Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College Street, Toronto, ON M5S3E5, Canada.
Chitosan, a cationic polysaccharide, has been found to improve the surface activity of lung surfactant extracts in the presence of various inhibitors. It has been proposed that chitosan binds to anionic lipids (e.g.
View Article and Find Full Text PDFBiochim Biophys Acta
March 2010
Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College Street, Toronto, ON M5S 3E5, Canada.
In this work four cationic additives were used to improve the surface activity of lung surfactants, particularly in the presence of bovine serum that was used as a model surfactant inhibitor. Two of those additives were chitosan in its soluble hydrochloride form with average molecular weights of 113kDa and 213kDa. The other two additives were cationic peptides, polylysine 50kDa and polymyxin B.
View Article and Find Full Text PDFColloids Surf B Biointerfaces
October 2009
Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Ontario, Canada.
This paper presents a continuation of the development of a drop shape method for film studies, ADSA-CSD (Axisymmetric Drop Shape Analysis-Constrained Sessile Drop). ADSA-CSD has certain advantages over conventional methods. The development presented here allows complete exchange of the subphase of a spread or adsorbed film.
View Article and Find Full Text PDFBiochim Biophys Acta
January 2008
Department of Chemical Engineering and Applied Chemistry, University of Toronto, 200 College Street, Toronto, ON, Canada M5S 3E5.
The interaction between a cationic polyelectrolyte, chitosan, and an exogenous bovine lung extract surfactant (BLES) was studied using dynamic compression/expansion cycles of dilute BLES preparations in a Constrained Sessile Drop (CSD) device equipped with an environmental chamber conditioned at 37 degrees C and 100% R.H. air.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!