Demonstration of magnetoelectric scanning probe microscopy.

Rev Sci Instrum

Department of Materials Science and Engineering, University of Maryland, College Park, Maryland 20742, USA.

Published: October 2007

A near-field room temperature scanning magnetic probe microscope has been developed using a laminated magnetoelectric sensor. The simple trilayer longitudinal-transverse mode sensor, fabricated using Metglas as the magnetostrictive layer and polyvinylidene fluoride as the piezoelectric layer, shows an ac field sensitivity of 467+/-3 microV/Oe in the measured frequency range of 200 Hz-8 kHz. The microscope was used to image a 2 mm diameter ring carrying an ac current as low as 10(-5) A. ac fields as small as 3 x 10(-10) T have been detected.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.2777197DOI Listing

Publication Analysis

Top Keywords

demonstration magnetoelectric
4
magnetoelectric scanning
4
scanning probe
4
probe microscopy
4
microscopy near-field
4
near-field room
4
room temperature
4
temperature scanning
4
scanning magnetic
4
magnetic probe
4

Similar Publications

Advancing Room-Temperature Magnetic Semiconductors with Organic Radical Charge Transfer Cocrystals.

Adv Mater

January 2025

Key Laboratory of Organic Integrated Circuits, Ministry of Education, Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, School of Science, Tianjin University, Tianjin, 300072, P. R. China.

Developing purely organic room-temperature magnetic semiconductors has been a long-sought goal in the material community toward the simultaneous control of spin and charge. Organic cocrystals, known for their structural versatility and multifunctionality, are ideal candidates for these magnetoelectric coupling applications. However, organic room-temperature magnetic semiconductor cocrystals have rarely been reported, and their mechanisms remain poorly understood due to the complexity of cocrystal structures.

View Article and Find Full Text PDF

Clinical motion analysis plays an important role in the diagnosis and treatment of mobility-limiting diseases. Within this assessment, relative (point-to-point) tracking of extremities could benefit from increased accuracy. Given the limitations of current wearable sensor technology, supplementary spatial data such as distance estimates could provide added value.

View Article and Find Full Text PDF

Background: Human immunodeficiency virus (HIV) establishes latent infections in cellular reservoirs, including microglia. HC69 cells, a microglial model of HIV latency, contain an HIV promoter long terminal repeat (LTR)-GFP reporter and were used for testing the efficacy of a two-step magnetoelectric nanoparticle (MENP) and extracellular vesicle (xEV) latency-targeting (MELT) nanotherapeutic. GFP expression in HC69 at rest is low (GFP), and upon exposure to LTR, transcription-activating agents (i.

View Article and Find Full Text PDF

Minimally invasive medical treatments for peripheral nerve stimulation are critically needed to minimize surgical risks, enhance the precision of therapeutic interventions, and reduce patient recovery time. Magnetoelectric nanoparticles (MENPs), known for their unique ability to respond to both magnetic and electric fields, offer promising potential for precision medicine due to their dual tunable functionality. In this study a multi-physics modeling of the MENPs was performed, assessing their capability to be targeted through external magnetic fields and become electrically activated.

View Article and Find Full Text PDF

Omnidirectional Wireless Power Transfer for Millimetric Magnetoelectric Biomedical Implants.

IEEE J Solid-State Circuits

November 2024

Department of Electrical and Computer Engineering, Rice University, Houston TX, 77005, USA.

Miniature bioelectronic implants promise revolutionary therapies for cardiovascular and neurological disorders. Wireless power transfer (WPT) is a significant method for miniaturization, eliminating the need for bulky batteries in today's devices. Despite successful demonstrations of millimetric battery-free implants in animal models, the robustness and efficiency of WPT are known to degrade significantly under misalignment incurred by body movements, respiration, heart beating, and limited control of implant orientation during surgery.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!