Research on polymer-gel dosimetry has been driven by the need for three-dimensional dosimetry, and because alternative dosimeters are unsatisfactory or too slow for that task. Magnetic resonance tomography is currently the most well-developed technique for determining radiation-induced changes in polymer structure, but quick low-cost alternatives remain of significant interest. In previous work, ultrasound attenuation and speed of sound were found to change as a function of absorbed radiation dose in polymer-gel dosimeters, although the investigations were restricted to one ultrasound frequency. Here, the ultrasound attenuation coefficient mu in one polymer gel (MAGIC) was investigated as a function of radiation dose D and as a function of ultrasonic frequency f in a frequency range relevant for imaging dose distributions. The nonlinearity of the frequency dependence was characterized, fitting a power-law model mu = af(b); the fitting parameters were examined for potential use as additional dose readout parameters. In the observed relationship between the attenuation coefficient and dose, the slopes in a quasi-linear dose range from 0 to 30 Gy were found to vary with the gel batch but lie between 0.0222 and 0.0348 dB cm(-1) Gy(-1) at 2.3 MHz, between 0.0447 and 0.0608 dB cm(-1) Gy(-1) at 4.1 MHz and between 0.0663 and 0.0880 dB cm(-1) Gy(-1) at 6.0 MHz. The mean standard deviation of the slope for all samples and frequencies was 15.8%. The slope was greater at higher frequencies, but so were the intra-batch fluctuations and intra-sample standard deviations. Further investigations are required to overcome the observed variability, which was largely associated with the sample preparation technique, before it can be determined whether any frequency is superior to others in terms of accuracy and precision in dose determination. Nevertheless, lower frequencies will allow measurements through larger samples. The fit parameter a of the frequency dependence, describing the attenuation coefficient at 1 MHz, was found to be dose dependent, which is consistent with our expectations, as polymerization is known to be associated with increased absorption of ultrasound. No significant dose dependence was found for the fit parameter b, which describes the nonlinearity with frequency. This is consistent with the increased absorption being due to the introduction of new relaxation processes with characteristic frequencies similar to those of existing processes. The data presented here will help with optimizing the design of future 3D dose-imaging systems using ultrasound methods.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/52/22/013DOI Listing

Publication Analysis

Top Keywords

attenuation coefficient
16
frequency dependence
12
cm-1 gy-1
12
gy-1 mhz
12
dose
9
frequency
8
polymer gel
8
ultrasound attenuation
8
radiation dose
8
nonlinearity frequency
8

Similar Publications

In clearance measurements involving a single material type, a conversion factor was applied to convert measurement results to activity based on an assumed uniform density. However, this factor has been found to underestimate activity in material mixtures. In this study, we proposed a method to identify the location with the lowest detection sensitivity (minimum location) in a mixture and evaluated its applicability to the conversion factor.

View Article and Find Full Text PDF

Field Investigation of Wave Attenuation in a Mangrove Forest Dominated by (Forsk.) Viern.

Plants (Basel)

January 2025

State Key Laboratory of Tropical Oceanography, South China Sea Institute of Oceanology, Chinese Academy of Sciences, Guangzhou 510301, China.

Based on field observation at the north coast of the Zhanjiang Bay in southern China, the characteristics of wave attenuation due to the drag force of one mangrove species, (Forsk.) Viern., were quantitatively analyzed.

View Article and Find Full Text PDF

Excavation of underground engineering structures involving deeply buried water-rich soft rocks is generally carried out using the artificial freezing method. A series of undrained uniaxial and triaxial shear and creep tests were conducted on soft rocks under different confining pressures (0, 0.2, 0.

View Article and Find Full Text PDF

Background: Deep learning-based segmentation of brain metastases relies on large amounts of fully annotated data by domain experts. Semi-supervised learning offers potential efficient methods to improve model performance without excessive annotation burden.

Purpose: This work tests the viability of semi-supervision for brain metastases segmentation.

View Article and Find Full Text PDF

Polymer nanocomposites have been investigated as lightweight and suitable alternatives to lead-based clothing. The present study aims to fabricate flexible, lead-free, X-ray-shielding composites using a polyvinyl chloride (PVC) matrix and different nanostructures. Four different nanostructures containing impure tungsten oxide, tungsten oxide (WO), barium tungstate (BaWO), and bismuth tungstate (BiWO) were synthesized through various methods.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!