A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Influence of paper electrocardiogram digitizing on T wave and QRS complex morphology parameters. | LitMetric

Influence of paper electrocardiogram digitizing on T wave and QRS complex morphology parameters.

Ann Noninvasive Electrocardiol

University of Oulu, Department of Electrical and Information Engineering, University of Oulu, Finland.

Published: October 2007

Background: Many morphological parameters of the electrocardiogram (ECG) can be calculated from a digital ECG and paper prints of ECG after digitizing. However, the digitizing process, including printing, scanning, ECG contour extraction, and alignment, can produce changes to the signals, reducing the reliability of some sensitive parameters of QRS complex and T wave.

Methods: The influence of the digitizing process on the parameters of T wave and QRS complex morphology was studied by comparing systematically the values of the nine ECG morphology parameters, computed from the digital ECG and the corresponding paper ECG. The robustness of the parameters to the digitizing process and their discrimination ability between healthy subjects and postinfarction patients were investigated.

Results: The standard T wave parameters and all selected dipolar loop-parameters retained their robustness and discrimination ability during the digitizing process of the paper ECGs. The non-dipolar parameters distorted strongly, especially those of the QRS complex. The T wave-based non-dipolar parameters retained their discrimination ability during the digitizing process.

Conclusions: The selected standard T wave parameters and the dipolar loop-parameters calculated from properly digitized ECG paper prints can be utilized in patient studies. Non-dipolar parameters distort strongly but T wave-based parameters retain discriminatory information.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC6932027PMC
http://dx.doi.org/10.1111/j.1542-474X.2007.00176.xDOI Listing

Publication Analysis

Top Keywords

qrs complex
16
digitizing process
16
parameters
12
discrimination ability
12
non-dipolar parameters
12
wave qrs
8
complex morphology
8
morphology parameters
8
ecg
8
digital ecg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!