Unlabelled: We compared SQ and ABQ diagnosis of VF imaged by radiography and X-ray absorptiometry. Mild ABQ VF had stronger associations with osteoporosis than mild SQ VF. Interobserver agreement (radiographic diagnosis) was better for ABQ.

Introduction: Vertebral fracture (VF) assessment from images acquired by X-ray absorptiometry (VFA) is often based on a semiquantitative approach (SQ); prevalent VF is identified if vertebral height appears reduced by >20%. Algorithm-based qualitative definition of osteoporotic VF (ABQ) requires evidence of endplate depression, and there is no threshold for reduction in vertebral height. The aims of this study were to (1) compare the prevalence of VFs; (2) compare the characteristics of women with and without VFs; (3) compare interobserver agreement; and (4) compare agreement between methods and imaging modalities for ABQ and SQ definitions of VFs.

Materials And Methods: Spine radiographs and absorptiometry images for 203 elderly women were assessed using ABQ (readers ABQ-1 and ABQ-2). These readings were compared with SQ assessments (readers SQ-1 and SQ-2) of the same images performed in a previous study. Agreement between readers and methods was assessed by kappa (kappa) statistics.

Results: The prevalence of VF was 15-18% (radiography) and 12-24% (VFA) for ABQ and SQ, respectively. Women with ABQ or SQ fractures were older and had lower BMD than those without fracture (p < 0.01). Mild ABQ (but not SQ) VF was associated with low BMD. Kappa scores for interobserver agreement for radiography and VFA, respectively, were as follows: ABQ, kappa = 0.74 (95% CI, 0.60, 0.87) and 0.65 (95% CI, 0.48, 0.81); SQ, kappa = 0.53 (95% CI, 0.46, 0.60) and 0.51 (95% CI, 0.44, 0.58). For agreement between ABQ-1 and SQ-1, kappa = 0.55 (95% CI, 0.39, 0.72) for radiography and 0.41 (95% CI, 0.25, 0.58 for VFA.

Conclusions: The prevalence of radiographic VF identified by ABQ and SQ was similar, but on VFA was 50% higher for SQ. Mild ABQ VF was associated with low BMD. Interobserver agreement for radiographic diagnosis was significantly better for ABQ than for SQ. Agreement between ABQ and SQ was moderate.

Download full-text PDF

Source
http://dx.doi.org/10.1359/jbmr.071032DOI Listing

Publication Analysis

Top Keywords

interobserver agreement
16
abq
13
mild abq
12
agreement
9
algorithm-based qualitative
8
vertebral fracture
8
agreement readers
8
imaging modalities
8
x-ray absorptiometry
8
agreement radiographic
8

Similar Publications

This study aimed to evaluate the efficacy of the single-energy metal artifact reduction (SEMAR) algorithm in reducing metal artifacts and enhancing image quality in contrast-enhanced computed tomography (CT) for patients undergoing endovascular aneurysm repair (EVAR) with coil embolization. Thirty-eight patients (mean age 81.0 ± 6 years; 31 men, 7 women) who underwent contrast-enhanced CT following EVAR and internal iliac artery coil embolization between September 2022 and May 2023 were retrospectively analyzed.

View Article and Find Full Text PDF

Objectives: To produce standards of references for quality control and assess the reproducibility of fetal ultrasound Doppler measurements commonly used for blood flow assessment in fetal growth.

Methods: Women with singleton normal pregnancies were prospectively recruited at University College London Hospital, UK, between 24 and 41 weeks. Umbilical artery (UA), middle cerebral artery (MCA), and their pulsatility indices (PI), resistance indices (RI) and ratios such as cerebro-placental (CPR) and umbilical cerebral ratio (UCR) were obtained twice by two sonographers in training or after completion of training, blind to each other's measurements.

View Article and Find Full Text PDF

Purpose: Pre-procedural imaging is critical for transcatheter mitral valve repair planning in patients with mitral valve disease. As differences among various measurement techniques for valve evaluation are still poorly understood, we sought to assess the intra- and interobserver agreement of complex measurements derived from a prototype mitral evaluation tool (Siemens) and a commercially available tool (CVI42) using both saddle- and D-shaped mitral annulus techniques.

Materials And Methods: Multiphasic cardiac computed tomography angiography data were loaded into each software.

View Article and Find Full Text PDF

Purpose: To compare the clinical and radiological features of gastric and small intestinal anisakiasis with those of gastric ulcers and Crohn's disease.

Materials And Methods: In this retrospective cohort study, 205 cases of anisakiasis (148 gastric; 53 small intestinal) were identified between July 2003 and February 2022. The control groups included 130 and 31 patients with gastric ulcers and Crohn's disease, respectively.

View Article and Find Full Text PDF

Rationale And Objectives: This study aimed to develop a predictive model for peritoneal metastasis (PM) in ovarian cancer using a combination radiomics and clinical biomarkers to improve diagnostic accuracy.

Patients And Methods: This retrospective cohort study of 619 ovarian cancer patients involved demographic data, radiomics, O-RADS standardized description, clinical biomarkers, and histological findings. Radiomics features were extracted using 3D Slicer and Pyradiomics, with selective feature extraction using Least Absolute Shrinkage and Selection Operator regression.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!