Unlabelled: We compared SQ and ABQ diagnosis of VF imaged by radiography and X-ray absorptiometry. Mild ABQ VF had stronger associations with osteoporosis than mild SQ VF. Interobserver agreement (radiographic diagnosis) was better for ABQ.
Introduction: Vertebral fracture (VF) assessment from images acquired by X-ray absorptiometry (VFA) is often based on a semiquantitative approach (SQ); prevalent VF is identified if vertebral height appears reduced by >20%. Algorithm-based qualitative definition of osteoporotic VF (ABQ) requires evidence of endplate depression, and there is no threshold for reduction in vertebral height. The aims of this study were to (1) compare the prevalence of VFs; (2) compare the characteristics of women with and without VFs; (3) compare interobserver agreement; and (4) compare agreement between methods and imaging modalities for ABQ and SQ definitions of VFs.
Materials And Methods: Spine radiographs and absorptiometry images for 203 elderly women were assessed using ABQ (readers ABQ-1 and ABQ-2). These readings were compared with SQ assessments (readers SQ-1 and SQ-2) of the same images performed in a previous study. Agreement between readers and methods was assessed by kappa (kappa) statistics.
Results: The prevalence of VF was 15-18% (radiography) and 12-24% (VFA) for ABQ and SQ, respectively. Women with ABQ or SQ fractures were older and had lower BMD than those without fracture (p < 0.01). Mild ABQ (but not SQ) VF was associated with low BMD. Kappa scores for interobserver agreement for radiography and VFA, respectively, were as follows: ABQ, kappa = 0.74 (95% CI, 0.60, 0.87) and 0.65 (95% CI, 0.48, 0.81); SQ, kappa = 0.53 (95% CI, 0.46, 0.60) and 0.51 (95% CI, 0.44, 0.58). For agreement between ABQ-1 and SQ-1, kappa = 0.55 (95% CI, 0.39, 0.72) for radiography and 0.41 (95% CI, 0.25, 0.58 for VFA.
Conclusions: The prevalence of radiographic VF identified by ABQ and SQ was similar, but on VFA was 50% higher for SQ. Mild ABQ VF was associated with low BMD. Interobserver agreement for radiographic diagnosis was significantly better for ABQ than for SQ. Agreement between ABQ and SQ was moderate.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1359/jbmr.071032 | DOI Listing |
Int J Cardiovasc Imaging
January 2025
Department of Cardiovascular Surgery, Jichi Medical University Saitama Medical Center, 1- 847 Amanuma-Cho, Omiya-Ku, Saitama, 330-8503, Japan.
This study aimed to evaluate the efficacy of the single-energy metal artifact reduction (SEMAR) algorithm in reducing metal artifacts and enhancing image quality in contrast-enhanced computed tomography (CT) for patients undergoing endovascular aneurysm repair (EVAR) with coil embolization. Thirty-eight patients (mean age 81.0 ± 6 years; 31 men, 7 women) who underwent contrast-enhanced CT following EVAR and internal iliac artery coil embolization between September 2022 and May 2023 were retrospectively analyzed.
View Article and Find Full Text PDFArch Gynecol Obstet
January 2025
Fetal Medicine Unit, Elizabeth Garrett Anderson Wing, University College London Hospitals NHS Foundation Trust, 250 Euston Road, London, NW1 2BU, UK.
Objectives: To produce standards of references for quality control and assess the reproducibility of fetal ultrasound Doppler measurements commonly used for blood flow assessment in fetal growth.
Methods: Women with singleton normal pregnancies were prospectively recruited at University College London Hospital, UK, between 24 and 41 weeks. Umbilical artery (UA), middle cerebral artery (MCA), and their pulsatility indices (PI), resistance indices (RI) and ratios such as cerebro-placental (CPR) and umbilical cerebral ratio (UCR) were obtained twice by two sonographers in training or after completion of training, blind to each other's measurements.
Radiol Med
January 2025
Department of Radiology, Mayo Clinic, 200 First Street SW, Rochester, MN, 55905, USA.
Purpose: Pre-procedural imaging is critical for transcatheter mitral valve repair planning in patients with mitral valve disease. As differences among various measurement techniques for valve evaluation are still poorly understood, we sought to assess the intra- and interobserver agreement of complex measurements derived from a prototype mitral evaluation tool (Siemens) and a commercially available tool (CVI42) using both saddle- and D-shaped mitral annulus techniques.
Materials And Methods: Multiphasic cardiac computed tomography angiography data were loaded into each software.
Jpn J Radiol
January 2025
Department of Radiology, St. Luke's International Hospital, 9-1 Akashi-cho, Chuo-ku, Tokyo, 104-8560, Japan.
Purpose: To compare the clinical and radiological features of gastric and small intestinal anisakiasis with those of gastric ulcers and Crohn's disease.
Materials And Methods: In this retrospective cohort study, 205 cases of anisakiasis (148 gastric; 53 small intestinal) were identified between July 2003 and February 2022. The control groups included 130 and 31 patients with gastric ulcers and Crohn's disease, respectively.
Acad Radiol
January 2025
Department of Ultrasound, The First Affiliated Hospital of Anhui Medical University, Hefei 230022, Anhui, China (Y.Z., Y.D., Q.Z., C.Z.). Electronic address:
Rationale And Objectives: This study aimed to develop a predictive model for peritoneal metastasis (PM) in ovarian cancer using a combination radiomics and clinical biomarkers to improve diagnostic accuracy.
Patients And Methods: This retrospective cohort study of 619 ovarian cancer patients involved demographic data, radiomics, O-RADS standardized description, clinical biomarkers, and histological findings. Radiomics features were extracted using 3D Slicer and Pyradiomics, with selective feature extraction using Least Absolute Shrinkage and Selection Operator regression.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!