A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of three commercial tests for buprenorphine screening in urine. | LitMetric

Background: Rapid and sensitive tests for detecting buprenorphine and its metabolites for drug-screening situations have been long awaited. From the tests available, we have evaluated two on-site drugs-of-abuse testing devices using competitive binding immunoassays and one homogeneous enzyme immunoassay measured on an automated analyser.

Methods: A total of 49 urine specimens were tested using three different kits. Two were point-of-care devices, a cassette test, QuikPac II OneStep Buprenorphine Test, and a strip test, QuikStrip OneStep Buprenorphine Test. The other was the CEDIA Buprenorphine Assay performed on a Roche Modular P analyser. The confirmation analyses were performed using liquid chromatography-mass spectrometry.

Results: The sensitivities of the three methods ranged from 88% to 100% and specificities from 91% to 100%. All three kits, especially the cassette and strip devices differed markedly from each other with respect to interpretation of the test result and to clarity of the test performance. Increasing the read time of the QuikStrip device from 5 to 30 min resulted in an increase in false-negative test results.

Conclusions: Our results indicate that special care should be taken when selecting immunology-based point-of-care methods for measurement of buprenorphine.

Download full-text PDF

Source
http://dx.doi.org/10.1258/000456307782268129DOI Listing

Publication Analysis

Top Keywords

three kits
8
onestep buprenorphine
8
buprenorphine test
8
test
7
buprenorphine
6
comparison three
4
three commercial
4
commercial tests
4
tests buprenorphine
4
buprenorphine screening
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!