Dichoptic nonius lines are used for subjectively (psychophysically) measuring vergence states, but they have been questioned as valid indicators of vergence eye position. In a mirror-stereoscope, we presented convergent and divergent step-stimuli and estimated the vergence response with nonius lines flashed at fixed delays after the disparity step stimulus. For each delay, an adaptive psychophysical procedure was run to determine the physical nonius offset required for subjective alignment; these vergence states were compared with objective eye movement recordings. Between both measures of initial vergence, we calculated the maximal cross-correlation coefficient: the median in our sample was about 0.9 for convergence and divergence, suggesting a good agreement. Relative to the objective measures, the subjective method revealed a smaller vergence velocity and a larger vergence response in the final phase of the response, but both measures were well correlated. The dynamic nonius test is therefore considered to be useful to relatively evaluate a subject's ability in disparity vergence.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.visres.2007.05.006 | DOI Listing |
J Vis
January 2025
Magic Leap Switzerland GmbH, Zürich, Switzerland.
When rendering the visual scene for near-eye head-mounted displays, accurate knowledge of the geometry of the displays, scene objects, and eyes is required for the correct generation of the binocular images. Despite possible design and calibration efforts, these quantities are subject to positional and measurement errors, resulting in some misalignment of the images projected to each eye. Previous research investigated the effects in virtual reality (VR) setups that triggered such symptoms as eye strain and nausea.
View Article and Find Full Text PDFStrabismus
January 2025
School of Optometry and Vision Science, University of Cape Coast, Cape Coast, Ghana.
The study sought to compare the number of cycles (NOS) for the first and second thirty-seconds (FASTS) within 1 min of accommodative facility (AF) and vergence facility (VF) testing to explore possibilities of reducing testing time to 30 s. In this cross-sectional study, a multistage sample of school children (aged 8-17 years) was taken through ocular-visual screening. Eligible participants (586) underwent refraction, stereo-acuity measurement, AF testing using ± 2D lens flippers, and VF testing using 3 BI/12 BO flipper prisms.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Department of Optometry and Vision Science, Faculty of Science and Technology, University of Latvia, Jelgavas Street 1, LV-1004 Riga, Latvia.
Eccentric photorefractometry is widely used to measure eye refraction, accommodation, gaze position, and pupil size. While the individual calibration of refraction and accommodation data has been extensively studied, gaze measurements have received less attention. PowerRef 3 does not incorporate individual calibration for gaze measurements, resulting in a divergent offset between the measured and expected gaze positions.
View Article and Find Full Text PDFJ Clin Med
December 2024
Ophthalmology Unit, Department of Medicine, Surgery and Neuroscience, University of Siena, 53100 Siena, Italy.
: Ocular proprioception is implicated in balance control and heterophoria is associated with abnormal posture, though previous research focused mainly on the role of vertical phoria and the use of vertical prisms. This study aims to evaluate whether ocular misalignment and prismatic correction of horizontal phoria affect posture. : Sixty-nine ( = 69) young healthy subjects were included and equally divided by horizontal distance phoria: orthophoria ( = 23), esophoria ( = 23) and exophoria ( = 23).
View Article and Find Full Text PDFGraefes Arch Clin Exp Ophthalmol
January 2025
Frankfurt Institute for Advanced Studies (FIAS), Frankfurt am Main, Germany.
Purpose: Our study presents a virtual reality-based tangent screen test (VTS) to measure subjective ocular deviations including torsion in nine directions of gaze. The test was compared to the analogous Harms tangent screen test (HTS).
Methods: We used an Oculus Go controller and head-mounted-display with rotation sensors to measure patient's head orientation for the VTS.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!