Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: The usefulness of fast fluid-attenuated inversion-recovery (FLAIR) sequences after administration of contrast medium (f-FLAIR (+)) has been shown in depicting brain tumors including metastases and meningeal carcinomatosis. Contrast-enhanced multi-shot echo-planar FLAIR (Ms-EPI-FLAIR (+)), comprising combined sequences of f-FLAIR (+) and Ms-EPI, may provide the advantages of f-FLAIR (+) along with rapid acquisition.
Purpose: To compare Ms-EPI-FLAIR (+) with post-contrast spin-echo T1-weighted imaging (SE-T1WI (+)) in the depiction of brain metastases.
Material And Methods: In 14 patients with metastatic tumors of the brain, spin-echo precontrast T1-weighted imaging (SE-T1WI (-)), fast spin-echo T2-weighted imaging (FSE-T2WI), fast-FLAIR, SE-T1WI (+), and Ms-EPI-FLAIR (+) were acquired. For qualitative evaluation of SE-T1WI (+) and Ms-EPI-FLAIR (+), receiver operating characteristic (ROC) analysis was performed in two different readers. For quantitative analysis, the intensity ratios (intensity of tumor divided by intensity of peritumoral region) in SE-T1WI (+) and Ms-EPI-FLAIR (+) were compared.
Results: Although pre-contrast f-FLAIR detected 84 of 106 tumors, Ms-EPI-FLAIR (+) detected 98 of 106 tumors. In the ROC analysis for observers A and B, Az values in SE-T1WI (+) did not differ from values in Ms-EPI-FLAIR (+). Quantitatively, the intensity ratio in Ms-EPI-FLAIR (+) also did not differ from that in SE-T1WI (+).
Conclusion: Detectability of brain metastases with Ms-EPI-FLAIR (+) is almost similar to that with SE-T1WI (+). Ms-EPI-FLAIR (+) could be an alternative to SE-T1WI (+) in the depiction of brain metastases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1080/02841850701499425 | DOI Listing |