The depolarisation ratio for the Raman-active phenyl stretching mode has been measured over the whole of the mesophase range, and the orientational order parameters deduced, in the uniaxial nematic liquid crystal octylcyanobiphenyl (8CB). Linearly polarised light was incident normally on a homogeneously aligned sample and a chi(2) minimisation routine performed on the 360 degrees depolarisation ratio profile. The order parameters (P(200)) and (P(400)), together with the differential polarisability ratio, r , are used as fitting parameters and measured as a function of temperature. Interestingly, we show that the value for r , conventionally measured in the isotropic phase and assumed to remain constant, has a clear temperature dependence, ranging from -0.032 + or - 0.008 in the isotropic phase through to -0.245 + or - 0.015 at the nematic-to-smectic A phase transition. The measured order parameters (P(200)) and (P(400)) varied from 0.35-0.55 + or - 0.02 and 0.180-0.245 + or - 0.02, respectively, across the 8 degrees C wide nematic phase range. The values of both (P(200)) and (P(400)) are in excellent agreement with theory, but it is noteworthy that (P(400)) shows a much better quantitative match than has been reported in previous work. Crucially the temperature dependence of r is shown to be a contributing factor in the low (P(400)) values that have been conventionally reported from Raman scattering measurements. The potential for fitting the entire angular depolarisation ratio distribution in liquid crystalline systems that are described by more order parameters, specifically biaxial materials, is discussed.

Download full-text PDF

Source
http://dx.doi.org/10.1140/epje/i2007-10223-3DOI Listing

Publication Analysis

Top Keywords

order parameters
20
depolarisation ratio
12
p200 p400
12
liquid crystal
8
parameters p200
8
isotropic phase
8
temperature dependence
8
parameters
6
order
5
p400
5

Similar Publications

In this study, a new deterministic mathematical model based on fractional-order derivative operator that describes the pseudo-recovery dynamics of an epidemiological process is developed. Fractional-order derivative of Caputo type is used to examine the effect of memory in the spread process of infectious diseases with pseudo-recovery. The well-posedness of the model is qualitatively investigated through Banach fixed point theory technique.

View Article and Find Full Text PDF

One of the primary challenges faced by small rubbing filament machines is the significant variability in material sizes, particularly in the feeding direction. This variability complicates the processing of locally baled straw with a single device. To address this issue, an adjustable feeding and bale-breaking device was developed and tested to enhance the filamentous performance of baled straw.

View Article and Find Full Text PDF

Constructions of solitary wave solutions for huge family of NPDEs with three applications.

PLoS One

January 2025

Department of Mathematics, Faculty of Science, Damietta University, New Damietta, Egypt.

This study offers closed-form solutions for the frequently utilised families of nonlinear partial differential equations (NPDEs). This form based on the He's semi-inverse technique. This form can be considered as a box solver for physicists, engineers and mathematicians.

View Article and Find Full Text PDF

The enduring pathogenicity of can be attributed to its lipid-rich cell wall, with mycolic acids (MAs) being a significant constituent. Different MAs' fluidity and structural adaptability within the bacterial cell envelope significantly influence their physicochemical properties, operational capabilities, and pathogenic potential. Therefore, an accurate conformational representation of various MAs in aqueous media can provide insights into their potential role within the intricate structure of the bacterial cell wall.

View Article and Find Full Text PDF

This work represents a comprehensive study of the ground vibrational state of C-13 substituted methanol using very high-resolution far-infrared (FIR) and infrared (IR) Synchrotron Radiation spectra recorded with a very high signal-to-noise (S/N) ratio in the entire region from 40to5000cm, at the Canadian Light sources. High resolution combined with a high S/N ratio allowed the recording to be done with an unprecedented resolution of about 0.0017cm.

View Article and Find Full Text PDF