Purpose: In craniospinal irradiation, both overlapping and gapping between the cranial and upper spinal field may occur due to patient's daily position (setup). This can cause dose inhomogeneities at the craniospinal junction. In this study we tried to find out possible dose changes at the craniospinal junction due to setup mistakes.
Materials And Methods: Both divergence matching technique (DMT) and half-beam block technique (HBBT) were used. At first step, a gap between cranial and spinal field borders was used, and at the second step overlapping between the fields for both techniques was applied. We irradiated films located in water equivalents solid phantoms with Co60 teletherapy machine.
Results: Dose homogeneity was 4% when no gap was used. When 2, 5, 8 and 10 mm gap were used, overlap occurred. Dose inhomogeneities were 6%, 17%, 27%,34% and 16%, 24%, 29%, 43%, respectively for DMT. Dose inhomogeneity was 5% with no gap used. With gaps of 2, 5, 8, and 10 mm, overlap occurred. Dose inhomogeneities were 8%, 12%, 36%, 51% and 17%, 29%, 35%, and 47%, respectively for HBBT.
Conclusion: With no gap or with 2mm gap between the fields the dose homogeneity is in acceptable dose variation limits (10%) for both techniques (DMT and HBBT). Beyond this distance the setup mistakes are not tolerable.
Download full-text PDF |
Source |
---|
Health Phys
January 2025
National Institute for Radiological Protection, Chinese Center for Disease Control and Prevention, Beijing, 100088, China.
Inhalation of 131I is the main route for internal doses to nuclear medicine workers. This study aimed to establish a simple analysis method for determining 131I activity in carbon cartridges, explore the activity concentration of 131I in nuclear medicine departments, and evaluate the internal dose of workers. A total of 21 nuclear medicine departments in the hospital conducted air sampling using a high-volume air sampler equipped with carbon cartridges and glass fiber filters to collect gaseous 131I and aerosol 131I, respectively.
View Article and Find Full Text PDFMol Ther
December 2024
National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, MD 20892, USA.
Asian Pac J Cancer Prev
December 2024
Department of Physics, Lovely Professional University, Phagwara, India.
Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.
Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.
Front Oncol
December 2024
Department of Radiation Oncology, The Third Affiliated Hospital of Kunming Medical University, Yunnan Tumor Hospital, Kunming, Yunnan, China.
Lung cancer is the most common malignant tumor in China. Its incidence and mortality rate increase year by year. In the synthesis treatment of lung cancer, radiotherapy (RT) plays a vital role, and radiation-induced lung injury(RILI) has become the major limiting factor in prescription dose escalation.
View Article and Find Full Text PDFJ Pharm Biomed Anal
February 2025
Department of Pharmacy, University of Patras, Rio, Achaias GR-26504, Greece. Electronic address:
Any polymorphic conversion of an active pharmaceutical ingredient (API), even if partial, is likely to lead to changes in its efficiency and safety. Posaconazole, an antifungal drug, is detected as Form-S in the commercially available oral suspensions. However, a mixture of Form-S and the initial Form I is likely to coexist depending either on the manufacturing process of the suspensions and/or to the storage conditions of the suspension.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!