Two major factors preventing the routine clinical use of finite-element analysis for image registration are: 1) the substantial labor required to construct a finite-element model for an individual patient's anatomy and 2) the difficulty of determining an appropriate set of finite-element boundary conditions. This paper addresses these issues by presenting algorithms that automatically generate a high quality hexahedral finite-element mesh and automatically calculate boundary conditions for an imaged patient. Medial shape models called m-reps are used to facilitate these tasks and reduce the effort required to apply finite-element analysis to image registration. Encouraging results are presented for the registration of CT image pairs which exhibit deformation caused by pressure from an endorectal imaging probe and deformation due to swelling.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TMI.2007.898810DOI Listing

Publication Analysis

Top Keywords

finite-element analysis
12
analysis image
8
image registration
8
boundary conditions
8
finite-element
5
automated finite-element
4
analysis deformable
4
registration
4
deformable registration
4
registration prostate
4

Similar Publications

Study on jet dynamic impact performance under the influence of standoff.

Sci Rep

December 2024

School of Mechanical and Electrical Engineering, North University of China, Taiyuan, 030051, Shanxi, China.

Due to the sensitivity of the shaped charge jet to standoff and the complexity of its impact under lateral disturbances, this study aims to investigate the dynamic impact evolution of the jet influenced by standoff and lateral disturbances. A finite element model for the dynamic impact of shaped charge jets was established. Dynamic impact experiments were designed and conducted to validate the effectiveness of the numerical simulations.

View Article and Find Full Text PDF

Microtextured microneedles are tiny needle-like structures with micron-scale microtextures, and the drugs stored in the microtextures can be released after entering the skin to achieve the effect of precise drug delivery. In this study, the skin substitution model of Ogden's hyperelastic model and the microneedle array and microtexture models with different geometrical parameters were selected to simulate and analyse the flow of the microtexture microneedle arrays penetrating the skin by the finite-element method, and the length of the microneedles was determined to be 200 μm, the width 160 μm, and the value of the gaps was determined to be 420 μm. A four-pronged cone was chosen as the shape of microneedles, and a rectangle was chosen as the shape of the drug-carrying microneedle.

View Article and Find Full Text PDF

It has long been speculated that the mechanical properties of the human oocyte can be an indicator for oocyte viability. Recent studies have demonstrated that embryo implantation rates, following Intra-Cytoplasmic Sperm Injection (ICSI) procedures, may be increased if the shear modulus value of the oocyte Zona Pellucida (ZP) is taken into consideration during embryo transfer. The shear modulus was determined by an iterative oocyte specific finite element (FE) analysis based on the clinical ICSI data.

View Article and Find Full Text PDF

Effects of capsulorhexis size and position on post-surgical IOL alignment.

Sci Rep

December 2024

Visual Optics Lab Antwerp (VOLANTIS), Faculty of Medicine and Health Sciences, University of Antwerp, Antwerp, Belgium.

In cataract surgery, post-surgical stability of the intraocular lens plays a major role. This study aims to explore how the size and decentration of the capsulorhexis affect intraocular lens decentration and tilt by using numerical methods. Finite element models included zonules, ciliary body, capsular bag, and an IOL with two open-loop haptics were built.

View Article and Find Full Text PDF

This study comprehensively compares dynamic and static forces in reinforced concrete (RC) beams, utilising experimental and finite element analysis (FEA) methodologies. Experimental tests involve monotonic two-point loading of 1 m x 150 mm x 150 mm RC beams using a universal testing machine (UTM). Deflection measurements are taken at three distinct locations (S1-S3) using various sensors, including force resisting sensor (FRS), flex sensor (FLS), MEMS accelerometer, and Piezoelectric sensors.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!