Comparison of Laplacian and bipolar ECGs for R-wave detection during noise.

Conf Proc IEEE Eng Med Biol Soc

Cardiac Rhythm Disease Manage., Medtronic Inc., Minneapolis, MN 55432, USA.

Published: March 2008

Body surface Laplacian mapping localizes cardiac activity and provides more detailed distributions compared to body surface potential mapping. Systematic comparison of the performance of bipolar and Laplacian ECGs during noise has not been performed. To determine whether Laplacian ECGs (2.5 cm diameter concentric rings) can reduce noise (myopotential and motion artifacts) and improve signal to noise ratio (SNR) compared to bipolar (4 cm spacing) ECGs, Laplacian and bipolar ECGs were recorded from the anterior (precordial V3) and lateral (precordial V6) chest regions in 25 patients undergoing posture changes and in-office exercises. Mean peak-to-peak (Vpp), root mean square noise (Noise(rms)) and SNR were computed across all activities and patients. Sensing performance using an R-wave detector with an auto-adjusting exponentially decaying threshold was assessed. Across all maneuvers, mean Vpp was larger for the bipolar ECG compared to the Laplacian ECG on the anterior (0.65 +/- 0.07 vs. 0.14 +/- 0.07 mV, p<0.05) and lateral (0.65 +/- 0.07 vs. 0.05 +/- 0.07 mV, p<0.05) regions. Laplacian ECGs resulted in least Noise(rms) compared to bipolar ECGs (anterior: 0.02 +/- 0.01 vs. 0.05 +/- 0.01, p<0.05; lateral: 0.01 +/- 0.01 vs. 0.07 +/- 0.01, p<0.05). Bipolar and Laplacian SNRs were comparable on the anterior chest (14.05 +/- 0.95 vs. 13.49 +/- 0.95, p=NS). On the lateral chest, bipolar SNR was larger than Laplacian SNR (13.78 +/- 0.95 vs. 8.67 +/- 0.96, p<0.05). Laplacian SNR on the anterior chest was larger compared to the lateral chest, confirming that Laplacian ECGs are sensitive to mapping location. Sensing performance showed that bipolar ECGs resulted in marginally superior sensing accuracy compared to Laplacian ECGs. In conclusion, Laplacian ECGs offer no advantage in SNR compared with standard bipolar ECGs.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2006.259381DOI Listing

Publication Analysis

Top Keywords

laplacian bipolar
8
bipolar ecgs
8
body surface
8
laplacian ecgs
8
+/- 007
8
bipolar
5
ecgs
5
noise
5
laplacian
5
comparison laplacian
4

Similar Publications

Objective: To determine the optimal montage and vocalization conditions for high-gamma language mapping using stereoelectroencephalography.

Methods: We studied 12 epilepsy patients who underwent invasive monitoring with depth electrodes and measurement of auditory-naming related high-gamma modulations. We determined the effects of electrode montage and vocalization conditions of the response on the high-gamma (60-140 Hz) amplitudes.

View Article and Find Full Text PDF

High-definition transcranial direct current stimulation desynchronizes refractory status epilepticus.

Neurotherapeutics

July 2024

Graduate Program in Biomedical Engineering, University of Manitoba, Winnipeg, Canada; Undergraduate Medical Education, Max Rady College of Medicine, University of Manitoba, Winnipeg, Canada; Section of Neurology, Department of Internal Medicine, University of Manitoba, Winnipeg, Canada.

Recently, we showed that high-definition transcranial direct current stimulation (hd-tDCS) can acutely reduce epileptic spike rates during and after stimulation in refractory status epilepticus (RSE), with a greater likelihood of patient discharge from the intensive care unit compared to historical controls. We investigate whether electroencephalographic (EEG) desynchronization during hd-tDCS can help account for observed anti-epileptic effects. Defining desynchronization as greater power in higher frequencies such as above 30 ​Hz ("gamma") and lesser power in frequency bands lower than 30 ​Hz, we analyzed 27 EEG sessions from 10 RSE patients who had received 20-minute session(s) of 2-milliamperes of transcranial direct current custom-targeted at the epileptic focus as previously determined by a clinical EEGer monitoring the EEG in real-time.

View Article and Find Full Text PDF

Identification of atrial fibrillation drivers by means of concentric ring electrodes.

Comput Biol Med

September 2022

Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain. Electronic address:

Background And Objective: The prevalence of atrial fibrillation (AF) has tripled in the last 50 years due to population aging. High-frequency (DFdriver) activated atrial regions lead the activation of the rest of the atria, disrupting the propagation wavefront. Fourier based spectral analysis of body surface potential maps have been proposed for DFdriver identification, although these approaches present serious drawbacks due to their limited spectral resolution for short AF epochs and the blurring effect of the volume conductor.

View Article and Find Full Text PDF

Hand gesture recognition using high-density surface electromyography (HD-sEMG) has gained increasing attention recently due its advantages of high spatio-temporal resolution. Convolutional neural networks (CNN) have also recently been implemented to learn the spatio-temporal features from the instantaneous samples of HD-sEMG signals. While the CNN itself learns the features from the input signal it has not been considered whether certain pre-processing techniques can further improve the classification accuracies established by previous studies.

View Article and Find Full Text PDF

Stereo-electroencephalography (SEEG) utilizes localized and penetrating depth electrodes to directly measure electrophysiological brain activity. The implanted electrodes generally provide a sparse sampling of multiple brain regions, including both cortical and subcortical structures, making the SEEG neural recordings a potential source for the brain-computer interface (BCI) purpose in recent years. For SEEG signals, data cleaning is an essential preprocessing step in removing excessive noises for further analysis.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!