PDMS and its suitability for analytical microfluidic devices.

Conf Proc IEEE Eng Med Biol Soc

Micro & Nanosyst. Res. Group, Institute of Automationa and Control, Tampere Univ. of Technol., Finland.

Published: March 2008

Poly(dimethylsiloxane) also known as PDMS is used in a wide range of biomedical applications. These range from implants through catheters to soft contact lenses. Therefore, it is understandable that PDMS has been extensively tested for these purposes. In past years, the microfluidics has moved from predominantly silicon and glass structures towards polymers due to their ease of manufacturing and moderate cost. PDMS has gained a lot of attention in various analytical applications. However, the testing of its suitability for such applications has not been as thorough as in the biomedical applications, perhaps relying on the experiments from that field. Microfluidic PDMS structures are more and more popular in various analytical devices. Such devices consume less reagents and can work with lower sample volumes. On the other hand, the surface-to-sample-volume ratio becomes larger. That increases the influence of material properties on the actual measurement. Some of the challenges include adsorption, diffusion, surface roughness, permeability and elasticity of PDMS, which are discussed in this paper.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2006.260465DOI Listing

Publication Analysis

Top Keywords

biomedical applications
8
pdms
6
pdms suitability
4
suitability analytical
4
analytical microfluidic
4
microfluidic devices
4
devices polydimethylsiloxane
4
polydimethylsiloxane pdms
4
pdms wide
4
wide range
4

Similar Publications

Advances in prostate-specific membrane antigen-targeted theranostics: from radionuclides to near-infrared fluorescence technology.

Front Immunol

January 2025

Department of Urology, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen, China.

Prostate-Specific Membrane Antigen (PSMA) is a highly expressed and structurally unique target specific to prostate cancer (PCa). Diagnostic and therapeutic approaches in nuclear medicine, coupling PSMA ligands with radionuclides, have shown significant clinical success. PSMA-PET/CT effectively identifies tumors and metastatic lymph nodes for imaging purposes, while -PSMA-617 (Pluvicto) has received FDA approval for treating metastatic castration-resistant PCa (mCRPC).

View Article and Find Full Text PDF

Objective: Type 2 diabetes mellitus (T2DM) is a chronic metabolic disorder that significantly impairs muscle regeneration following injuries, contributing to numerous complications and reduced quality of life. There is an urgent need for therapeutic strategies that can enhance muscle regeneration and alleviate these pathological mechanisms. In this study, we evaluate the therapeutic efficacy of W-GA nanodots, which are composed of gallic acid (GA) and tungstate (W6+), on muscle regeneration in type 2 diabetes mellitus (T2D)-induced muscle injury, with a focus on their anti-inflammatory and antioxidative effects.

View Article and Find Full Text PDF

Lightweight Retinal Layer Segmentation With Global Reasoning.

IEEE Trans Instrum Meas

May 2024

School of Mechanical Engineering, Shandong University, Jinan 250061, Shandong, China.

Automatic retinal layer segmentation with medical images, such as optical coherence tomography (OCT) images, serves as an important tool for diagnosing ophthalmic diseases. However, it is challenging to achieve accurate segmentation due to low contrast and blood flow noises presented in the images. In addition, the algorithm should be light-weight to be deployed for practical clinical applications.

View Article and Find Full Text PDF

Targeted barcoding of variable antibody domains and individual transcriptomes of the human B-cell repertoire using Link-Seq.

PNAS Nexus

January 2025

Institute of Bioengineering, School of Engineering, École Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland.

Here, we present Link-Seq, a highly efficient droplet microfluidic method for combined sequencing of antibody-encoding genes and the transcriptome of individual B cells at large scale. The method is based on 3' barcoding of the transcriptome and subsequent single-molecule PCR in droplets, which freely shift the barcode along specific gene regions, such as the antibody heavy- and light-chain genes. Using the immune repertoire of COVID-19 patients and healthy donors as a model system, we obtain up to 91.

View Article and Find Full Text PDF

Significance: Cerebral blood flow (CBF) and cerebral blood volume (CBV) are key metrics for regional cerebrovascular monitoring. Simultaneous, non-invasive measurement of CBF and CBV at different brain locations would advance cerebrovascular monitoring and pave the way for brain injury detection as current brain injury diagnostic methods are often constrained by high costs, limited sensitivity, and reliance on subjective symptom reporting.

Aim: We aim to develop a multi-channel non-invasive optical system for measuring CBF and CBV at different regions of the brain simultaneously with a cost-effective, reliable, and scalable system capable of detecting potential differences in CBF and CBV across different regions of the brain.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!