In late years, f-MRI (functional magnetic resonance imaging) are used for analysis of a visual function. In case of the study for a visual function, the checker flag pattern consists of white square and black square is usually used for sight stimulation. In sight stimulation using this pattern, a color of square (black and white) changes alternately at constant frequency. It is usually called pattern reversal stimulation. When this pattern is used for stimulation, the subject sometimes feels movement for the shown stimulation pattern. We think that this sensation of movement relates to spatial frequency (that means the size of a square of a stimulation pattern) of a stimulation image and a turning over frequency of a stimulation pattern strongly. Our objectives of this study are the following. 1) Clarify a part of the brain that is a cause of this moving sensation. 2) Investigate the relationship among the magnitude of this sensation, spatial frequency and turning over frequency. Three normal adults were used for the subject. This time, turning over frequency was changed to 8 Hz by 1 Hz step under fixed spatial frequency. Under this condition, we examined the state of activation of a V1 area. In addition, we examined whether BOLD effect varied with a change of a stimulation color. In this experiment, we used blue and yellow color instead of black and white for stimulation, and the reaction was examined.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2006.260013DOI Listing

Publication Analysis

Top Keywords

stimulation pattern
20
turning frequency
16
spatial frequency
12
stimulation
10
frequency
8
visual function
8
square black
8
sight stimulation
8
black white
8
pattern stimulation
8

Similar Publications

Tachistoscopic studies have established a right field advantage for the perception of visually presented words, which has been interpreted as reflecting a left hemispheric specialization. However, it is not clear whether this is driven by the linguistic task of word processing, or also occurs when processing properties such as the style and regularity of text. We had 23 subjects perform a tachistoscopic study while they viewed five-letter words in either computer font or handwriting.

View Article and Find Full Text PDF

Background: The Needs Assessment Framework (NAF) stimulates awareness of care staff to consider perspectives of clients with intellectual disabilities in decisions on involuntary care. We explored the effect of implementers' participation in a Virtual Community-of-Practice (VCoP) for designing implementation plans, on NAF implementation and staff awareness.

Method: A quasi-experimental design was used to compare implementation and awareness by care staff (n = 54) between organisations that implemented NAF with VCoP participation (N = 4) and organisations that implemented NAF as usual (N = 3).

View Article and Find Full Text PDF

The complex interaction between circadian rhythms and physiological functions is essential for maintaining human health. At the heart of this interaction lies the PERIOD proteins (PERs), pivotal to the circadian clock, influencing the timing of physiological and behavioral processes and impacting oxidative stress, immune functionality, and tumorigenesis. PER1 orchestrates the cooperation of the enzyme GPX1, modulating mitochondrial dynamics in sync with daily rhythms and oxidative stress, thus regulating the mechanisms managing energy substrates.

View Article and Find Full Text PDF

Background: Effects of subthalamic nucleus deep brain stimulation (STN-DBS) on neuropsychiatric symptoms of Parkinson's disease (PD) remain debated. Sensor technology might help to objectively assess behavioural changes after STN-DBS.

Case Presentation: 5 PD patients were assessed 1 before and 5 months after STN-DBS with the Movement Disorders Society Unified Parkinson's Disease Rating Scale part III in the medication ON (plus postoperatively stimulation ON) condition, the Montreal Cognitive Assessment, the Questionnaire for Impulsive-Compulsive Behaviors in Parkinson's Disease Rating Scale present version, the Hospital Anxiety and Depression Scale and the Starkstein Apathy Scale.

View Article and Find Full Text PDF

Robot-assisted vs. manual cochlear implant electrode array insertion in four children.

Eur Arch Otorhinolaryngol

January 2025

Department of Audiovestibology, ASST dei Sette Laghi, Via Lazio, 21100, Varese, VA, Italy.

Purpose: Evaluate the feasibility and safety of a robotic electrode insertion in pediatric cochlear implantation and compare the results with manually inserted electrodes in the same subject.

Methods: Retrospective case series review of four children who underwent bilateral cochlear implantation with the same array: on one side, the array was inserted using the robot, while on the other side the array was inserted manually. Behavioural and electrophysiological measures were compared.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!