A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Aortic thrombus segmentation using narrow band active contour model. | LitMetric

Aortic thrombus segmentation using narrow band active contour model.

Conf Proc IEEE Eng Med Biol Soc

Imaging Technology, GE Global Research, Bangalore, India.

Published: March 2008

This paper proposes 2D active contour approach for segmenting thrombus volume from 3D CT images of abdominal aortic aneurysm (AAA). The major challenges in segmenting thrombus are in part because of lack of delineating contrast at anatomical boundaries due to overlap of other soft tissues and artifacts arising from stents and calcium deposits. In the present approach first the bone structures are removed from the image so that these nearby high intensity regions do not interfere in the segmentation process. Next morphological operation is done on the bone-removed image to reduce the effect of streak artifacts. The order of these two operations can be inter-changed. Then, a manual contour is initialized on an axial slice of the pre-processed image and deformed and subsequently propagated to the consecutive slices for deformation. The snake process is governed by force field defined by intensity-based object-ness measure within a band defined by local image properties. The proposed algorithm has been tested on 7 CT images and compared with the ground truth obtained from manual segmentation by radiologist and accuracy between the range 93.16% to 85.08% is observed.

Download full-text PDF

Source
http://dx.doi.org/10.1109/IEMBS.2006.260125DOI Listing

Publication Analysis

Top Keywords

active contour
8
segmenting thrombus
8
aortic thrombus
4
thrombus segmentation
4
segmentation narrow
4
narrow band
4
band active
4
contour model
4
model paper
4
paper proposes
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!