Objective: To determine the diagnostic accuracy of ultrasonographically (US) and stereotactically guided fine needle aspiration cytology (FNAC) for the diagnosis of non-palpable breast lesions.

Patients And Methods: From January 2002 to December 2004, 470 women with 478 mammographically detected non-palpable breast lesions had US or stereotactically guided FNAC of the breast lesion. Subsequent histological evaluation of the same lesion was performed at the Institute of Oncology Ljubljana, Slovenia. The correlation between the original cytological and histological diagnosis was assessed and the sensitivity, specificity, positive predictive value and negative predictive value were calculated.

Results: Among US-guided FNACs, 144 (53.5%) were histologically verified benign lesions and 125 (46.5%) were carcinomas. Cytological diagnoses were: true positive (TP) in 63 cases (50.4%), suspicious in 35 (28%), false negative (FN) in eight (6.4%), and in 19 (15.2%) cases, the material was inadequate for diagnosis. In the stereotactically guided FNAC group, there were 209 women with 209 lesions, with 95 (45%) histologically proven carcinomas and 114 (55%) benign lesions. Cytological diagnoses were TP in 49 (51.6%) cases, true suspicious in 21 (22.1%), FN in nine (9.5%), and in 16 (16.8%) cases, the material was not adequate for the diagnosis.

Conclusion: The sensitivity of 88.7% and specificity of 98.6% for US-guided FNAC and 84.5% and 100% for stereotactically guided FNAC, respectively, suggest that clinicians can rely upon cytological diagnosis for planning further management of women with non-palpable breast lesions.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1365-2303.2007.00516.xDOI Listing

Publication Analysis

Top Keywords

stereotactically guided
20
non-palpable breast
16
breast lesions
12
guided fnac
12
ultrasonographically stereotactically
8
aspiration cytology
8
benign lesions
8
cytological diagnoses
8
cases material
8
lesions
6

Similar Publications

Assessing Malignant Risk in B3 Breast Lesions: Clinical Insights and Implications.

J Clin Med

December 2024

Multidisciplinary Breast Centre, Dipartimento Scienze della Salute della Donna e del Bambino e di Sanità Pubblica, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, 00168 Rome, Italy.

: B3 breast lesions, characterized by uncertain malignant potential, pose a significant challenge for clinicians. With the increasing use of preoperative biopsies, there is a need for careful management strategies, including watchful waiting, vacuum-assisted excision (VAE), and surgery. This study aims to assess the concordance between preoperative biopsy findings and postoperative histology, with a focus on evaluating the positive predictive value (PPV) for malignancy in B3 lesions.

View Article and Find Full Text PDF

Oligometastatic prostate cancer (OMPC) represents an intermediate state in the progression from localized disease to widespread metastasis when the radiographically significant sites are limited in number and location. With no clear consensus on a definition, its diagnostic significance and associated optimal therapeutic approach remain controversial, posing a significant challenge for clinicians. The current standard of care for metastatic disease is to start systemic therapy; however, active surveillance and targeted radiotherapy have become attractive options to mitigate the long-term effects of androgen deprivation therapy (ADT).

View Article and Find Full Text PDF

Purpose: To use imaging data from stereotactic MR-guided online adaptive radiotherapy (SMART) of ultracentral lung tumors (ULT) for development of a safe non-adaptive approach towards stereotactic body radiotherapy (SBRT) of ULT.

Patients And Methods: Analysis is based on 19 patients with ULT who received SMART (10 × 5.0-5.

View Article and Find Full Text PDF

Stereotactic systems have traditionally used Cartesian coordinate combined with linear algebraic mathematical models to navigate the brain. Previously, the development of a novel stereotactic system allowed for improved patient comfort, reduced size, and carried through a simplified interface for surgeons. The system was designed with a work envelope and trajectory range optimized for deep brain stimulation applications only.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!