Skeletal metastases are a major source of morbidity for cancer patients. The purpose of this study was to evaluate the effects of megavoltage irradiation and antiangiogenic therapy on metastatic bone cancer. A tumor xenograft model was prepared in C3H/Scid mice using 4T1 murine breast carcinoma cells. Twenty-eight mice bearing tumors were treated with either bevacizumab (15 mg/kg), local megavoltage irradiation (30 Gy in 1 fraction), combination of bevacizumab and local megavoltage irradiation or physiologic saline solution (control group). Tumor area, bone destruction, tumor microvessel density, pain-associated behaviors and expression of substance P were assessed. Combined modality treatment reduced the frequency of pain-associated behaviors, decreased levels of nociceptive protein expression in the spinal cord, maintained cortical integrity and decreased the density of microvessels as compared to single modality treatments. We conclude that concurrent antiangiogenic therapy and localized radiotherapy for the treatment of bone metastases warrants further evaluation in human clinical trials.

Download full-text PDF

Source
http://dx.doi.org/10.1002/ijc.23157DOI Listing

Publication Analysis

Top Keywords

megavoltage irradiation
12
combination bevacizumab
8
bone destruction
8
bone metastases
8
antiangiogenic therapy
8
local megavoltage
8
pain-associated behaviors
8
bone
5
local irradiation
4
irradiation combination
4

Similar Publications

Utility of photon-counting detectors for MV-kV dual-energy computed tomography imaging.

J Med Imaging (Bellingham)

December 2024

University of Chicago, Department of Radiology, Chicago, Illinois, United States.

Purpose: High soft-tissue contrast imaging is essential for effective radiotherapy treatment. This could potentially be realized using both megavoltage and kilovoltage x-ray sources available on some therapy treatment systems to perform "MV-kV" dual-energy (DE) computed tomography (CT). However, noisy megavoltage images obtained with existing energy-integrating detectors (EIDs) are a limiting factor for clinical translation.

View Article and Find Full Text PDF

Aim: To study the dosimetric behavior of dose computational algorithms in inhomogeneous medium using CMS XiO and MONACO treatment planning system (TPS) for 4 megavoltage (MV), 6 MV and 15 MV photon beam energies.

Material And Methods: Styrofoam blocks of thickness 1.90 cm, 3.

View Article and Find Full Text PDF

Purpose: Moderate hypofractionation (MHF) offers logistical and financial advantages, and has become standard in Western countries but not yet in Africa. This study assessed GI and genitourinary (GU) acute toxicity in Rwandan men undergoing MHF (20 × 3 Gy) treatment.

Materials And Methods: Since 2021, patients with prostate cancer at the Rwanda Cancer Centre have been informed about the study on MHF treatment and could participate by signing an informed consent.

View Article and Find Full Text PDF

Over the past decade, our institution delivered conventional total body irradiation (TBI) using Elekta's Monaco treatment planning system (TPS) with an extended SSD field arrangement and 18 megavoltage (MV) energy lateral fields. In 2020, there was a transition to the Eclipse™ treatment planning system and Truebeam® linear accelerators with 6 MV and 10 MV energies. These changes meant that essential components of the existing technique were unavailable for clinical use and a new approach to the institution technique was required to ensure continuation of service.

View Article and Find Full Text PDF

Comparative effectiveness of kilo- and megavoltage energies in low-dose radiotherapy for painful degenerative musculoskeletal diseases: a systematic review and meta-analysis.

Strahlenther Onkol

December 2024

Department of Radiation Oncology, Seoul National University College of Medicine, SMG-SNU Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, 07061, Seoul, Korea (Republic of).

Purpose: This study aimed to assess the impact of different energy levels on the effectiveness of low-dose radiotherapy (LDRT) for treating painful degenerative musculoskeletal diseases, as comparative efficacy data are currently lacking.

Methods: A systematic review was conducted in PubMed, Embase, and the Cochrane Library databases to identify studies with response information on the energy used (kilovoltage [kV] vs. megavoltage [MV]).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!