A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparative study of the transverse strength of three denture base materials. | LitMetric

Comparative study of the transverse strength of three denture base materials.

J Dent

Section of Restorative and Prosthetic Dentistry, The Ohio State University College of Dentistry, 305 West 12th Avenue, #191, P.O. Box 182357, Columbus, OH 43218-2357, USA.

Published: December 2007

Objectives: Fracture resistance of recently introduced denture base resins has not been compared to traditional denture base materials. This study compared the transverse strength of three denture base materials, namely, Lucitone 199, Triad VLC, and the newly introduced Eclipse.

Materials And Methods: A total of 30 specimens (50mmx25mmx2.5mm) were fabricated, 10 from each material. The specimens were loaded until failure on an Instron universal testing machine using a three point flexural test. One-way analysis of variance (ANOVA) was used to compare the mean transverse strength between the three materials tested.

Results: The transverse strength values showed significant differences between the three denture base materials (P<0.0001). The mean transverse strength and standard deviations (MPa) were as follows: Eclipse 116.13+/-17.7, Lucitone 87.12+/-8.1, and Triad VLC 57.96+/-7.3.

Conclusions: Within the limitations of this study, Eclipse showed the highest transverse strength among the materials tested. Eclipse denture base material may provide a stronger alternative to traditional denture base resins.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jdent.2007.09.006DOI Listing

Publication Analysis

Top Keywords

denture base
20
transverse strength
16
base materials
16
strength three
12
three denture
12
three
5
denture
5
base
5
materials
5
comparative study
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!