A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Immunoaffinity in-tube solid phase microextraction coupled with liquid chromatography-mass spectrometry for analysis of fluoxetine in serum samples. | LitMetric

Immunoaffinity in-tube solid phase microextraction coupled with liquid chromatography-mass spectrometry for analysis of fluoxetine in serum samples.

J Chromatogr A

Departamento de Química, Faculdade de Filosofia Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901 Ribeirao Preto, SP, Brazil.

Published: December 2007

The inherent selectivity of the antibody was combined with in-tube solid-phase microextraction by immobilization of the antibody into the fused silica capillary. A sensitive, selective, and reproducible immunoaffinity in-tube solid-phase microextraction coupled with liquid chromatography-mass spectrometry (in-tube SPME/LC-MS) method was developed, and validated for fluoxetine analysis in human serum. Important factors in the optimization of in-tube SPME variables, as well as the evaluation of the immunoaffinity capillary capacity are discussed. The in-tube SPME/LC-MS method presented a limit of quantitation of 5.00 ng/mL, and precision intra-assays with RSDs lower than 5%. The response of the in-tube SPME/LC-MS method for fluoxetine was linear over a dynamic range from 5.00 to 50.00 ng/mL, with correlation coefficients better than 0.998. Based on analytical validation it was demonstrated that in-tube SPME/LC-MS method offers high sensitivity, selectivity, and enough reproducibility to permit the quantification of fluoxetine in human serum at therapeutic levels. Thus, the proposed SPME/LC method can be useful tool to determine fluoxetine serum concentrations in patients receiving therapeutic dosages.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2007.09.026DOI Listing

Publication Analysis

Top Keywords

in-tube spme/lc-ms
16
spme/lc-ms method
16
immunoaffinity in-tube
8
microextraction coupled
8
coupled liquid
8
liquid chromatography-mass
8
chromatography-mass spectrometry
8
fluoxetine serum
8
in-tube solid-phase
8
solid-phase microextraction
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!