The objective of this study was to determine the effect of different prosthetic systems on the functional and radiographic outcomes after shoulder arthroplasty for fractures. This study comprised 35 patients (28 women and 7 men) with a mean age of 74 years (range, 56-88 years) who sustained 4-part fractures of the proximal humerus and were randomly allocated to 2 different groups regarding the type of prosthesis. The 2 systems used differ mainly in the type of fixation of the tuberosities. In group 1 (EPOCA), the fixation was achieved with wire cables through a medial and a lateral hole in the stem, whereas in group 2 (HAS), the fixation was performed by use of transosseous braided sutures. After a follow-up of 1 year, the functional and radiographic outcomes were evaluated. The retrieved data demonstrate that rigid fixation and anatomic positioning of the tuberosities (group 1) increase the rate of bony healing superior to all other factors. There was a statistically significant difference regarding the relative individual Constant score (P = .001) and the mean active range of motion (flexion, P < .001; abduction, P = .001; external rotation in adduction, P = .01; and external rotation in 90 degrees abduction, P = .001) when both groups were compared, showing a better outcome in the EPOCA group for all parameters. Radiologic findings, like heterotopic ossification, glenoid erosion, or subluxation, had no significant influence on the outcome in this study. Accurate placement of the tuberosities and healing at the bone-bone interface of the rotator cuff seem to be the most important factors influencing the outcome in prosthetic care of fractures.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jse.2007.07.002DOI Listing

Publication Analysis

Top Keywords

fractures proximal
8
proximal humerus
8
functional radiographic
8
radiographic outcomes
8
tuberosities group
8
abduction 001
8
external rotation
8
primary hemiarthroplasty
4
hemiarthroplasty four-part
4
fractures
4

Similar Publications

Background: To explore the advantages of a lateral tibial locking plate combined with Jail screw fixation in the treatment of anterolateral tibial plateau collapse fracture (ATPCF).

Methods: A retrospective analysis was conducted on patients with ATPCFs admitted to our hospital from February 2019 to February 2023. Twenty-six patients were successfully included, including 15 males and 11 females, with an average age of 58.

View Article and Find Full Text PDF

Background: Tibial bone fractures in the malleolar regions are a major concern during the early postoperative period of total ankle replacement (TAR), affecting patient outcomes such as stability and recovery. Design, placement, and anatomic misalignment of implant components can contribute to malleolar fractures. The aim of this study is to understand the influence of implant design features, including keel, peg, stem, and bar type design, and bone-implant interfacial conditions on malleolar fracture following TAR.

View Article and Find Full Text PDF

The Predictive Value of Multifidus Degeneration in Osteoporotic Vertebral Compression Fracture Patients with Kyphosis Deformity.

Spine J

January 2025

Orthopedic Department, Peking University Third Hospital, 49 North Garden Road, Haidian District, Beijing 100191, China; Engineering Research Center of Bone and Joint Precision Medicine, 49 North Garden Road, Haidian District, Beijing 100191, China; Beijing Key Laboratory of Spinal Disease Research, 49 North Garden Road, Haidian District, Beijing 100191, China. Electronic address:

Background Context: Osteoporotic vertebral compression fracture (OVCF) causes pain, kyphosis and neurological damage, which significantly affect patients' quality of life. Patients with OVCF are often elderly and have severe osteoporosis, which makes preoperative symptom more serious, postoperative recovery worse and the incidence of postoperative complications high. The paraspinal muscles have been well studied in adult spinal deformities, but there is no conclusive evidence that their findings can be applied to OVCF.

View Article and Find Full Text PDF

Purpose: While treatment modalities for Maisonneuve fractures involving the proximal third of the fibula are established, no studies to date have reported outcomes associated with syndesmotic-only fixation of middle third fibular shaft fractures. The purpose of this study was to evaluate outcomes associated with syndesmotic-only fixation in the treatment of Maisonneuve fractures involving the middle third of the fibula.

Methods: A retrospective review was conducted on 257 cases of syndesmotic ankle instability with associated fibular fractures at a level 1 trauma center between 2013 and 2023.

View Article and Find Full Text PDF

Removal of spontaneously fractured leads with their proximal ends migrated into the vascular space has not been analysed in detail thus far. The study aimed to compare the effectiveness of different approaches and auxiliary tools for removing fractured leads with migrated proximal ends. Retrospective analysis of 72 cases from a database containing 3847 TLEs (transvenous lead extraction).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!