A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Polypyrrole-glucose oxidase biosensor. Effect of enzyme encapsulation in multilamellar vesicles on analytical properties. | LitMetric

In this paper, we present the analytical properties of a new type of polypyrrole-based, enzymatic amperometric biosensor. It is produced by encapsulating the enzyme, glucose oxidase (GOx), into onion-type multilamellar vesicles (MLV). We compare its properties to those of a classical GOx-polypyrrole biosensor. When MLV are used to embed GOx in polypyrrole (PPy), GOx behaves as a Michaelis-Menten enzyme. Without MLV, a deviation to the Michaelis-Menten behaviour is observed for high glucose concentrations. Kinetics parameters of both types of biosensors are studied as a function of the surface charge synthesis: GOx encapsulation induces a 200-fold increase of the apparent maximal current (I(m)(app)) and a 10-fold increase of the apparent Michaelis constant (K(m)(app)). Sensitivity is improved by a factor of 5. GOx is also shown to be less sensitive to inhibiting ions (Cl(-)) when MLV are used. A residual amperometric response of 43% instead of 3% is measured. Finally, the long-term stability of biosensors is improved by the GOx encapsulation. All these results are partially explained by our previous study on the morphology of PPy films fabricated with GOx encapsulated into onion-type MLV (Olea et al., 2007).

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bios.2007.08.018DOI Listing

Publication Analysis

Top Keywords

multilamellar vesicles
8
analytical properties
8
gox encapsulation
8
increase apparent
8
gox
7
mlv
5
polypyrrole-glucose oxidase
4
oxidase biosensor
4
biosensor enzyme
4
enzyme encapsulation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!