Variability of electrode positions using electrode caps.

Brain Topogr

Auditory Neuroscience Laboratory, The University of South Dakota, 414 East Clark Street, Vermillion, SD 57069, USA.

Published: January 2008

We investigated the variability of electrode positions for a multi-channel, custom electrode cap placed onto participants' heads without taking scalp measurements. The electrode positions were digitized in a three-dimensional space for 10 young adult participants on three separate occasions. Positional variability was determined for 15 selected electrodes within the three-dimensional preauricular-nasion (PAN) coordinate system and from this system, angular coordinate variability was also determined. The standard deviations of the 15 selected electrodes ranged from 3.0 to 12.7 mm in the PAN system. These data resulted in a variability of 2.0 degrees to 10.4 degrees among the angular coordinates. The measurements indicated slightly greater variability of electrode positions compared to studies when electrodes were placed using scalp measurements. The implication of this study is that the use of electrode caps may not be appropriate when electroencephalographic (EEG) or evoked potential (EP) techniques depend on accurate electrode placement. Additionally, if a longitudinal study is performed, electrode locations should be checked to ensure that they conform with previous sessions.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10548-007-0036-zDOI Listing

Publication Analysis

Top Keywords

electrode positions
16
variability electrode
12
electrode
8
electrode caps
8
scalp measurements
8
variability determined
8
selected electrodes
8
variability
6
positions
4
positions electrode
4

Similar Publications

Advancing cancer therapy with custom-built alternating electric field devices.

Bioelectron Med

January 2025

School of Pharmacy, Biodiscovery Institute & Boots Science Building, University of Nottingham, Nottingham, NG7 2RD, UK.

Background: In glioblastoma (GBM) therapy research, tumour treating fields by the company Novocure™, have shown promise for increasing patient overall survival. When used with the chemotherapeutic agent temozolomide, they extend median survival by five months. However, there is a space to design alternative systems that will be amenable for wider use in current research.

View Article and Find Full Text PDF

Introduction: Intraoperative microelectrode recording (MER) and intraoperative test stimulation may provide vital information for optimal electrode placement and clinical outcome in movement disorders patients treated with deep brain stimulation (DBS). The aims of this retrospective study were to determine (i) how often the planned (imaging based) placements of electrodes were changed due to MER and intraoperative test stimulation in Parkinson's disease (PD), dystonia and essential tremor (ET) patients; (ii) whether the frequency of repositioning changed over time; (iii) whether patients' age or disease duration (in PD) influenced the frequency of repositioning.

Methods: Data on the planned and the final placement of 141 electrodes in 72 consecutive DBS treated patients (52 PD, 11 dystonia, 9 ET) was collected over the first 8 years of DBS implementation in a single center.

View Article and Find Full Text PDF

This work proposes a large aperture liquid crystal lens array based on a novel layered combined electrode (LCE) structure. A large aperture (800µm) is achieved by strategically positioning pixel electrodes on either side of the LC lens and auxiliary electrodes at its center. This design effectively doubles the LC lens aperture compared to conventional structures, achieving this at a significantly lower voltage.

View Article and Find Full Text PDF

In this study, the dispersion behavior of MoS₂ in ionic liquids (ILs) with varying alkyl chain lengths was the primary focus of investigation, followed by the design of a novel PAM/SMA/CMC/PDA@MoS hydrogel. By optimizing the concentrations of CMC and PDA@MoS, a bifunctional hydrogel with both sensing and catalytic functions was successfully developed. Mechanical tests revealed that the PAM/SMA/CMC/0.

View Article and Find Full Text PDF

Electroencephalographic signals are obtained by amplifying and recording the brain's spontaneous biological potential using electrodes positioned on the scalp. While proven to help find changes in brain activity with a high temporal resolution, such signals are contaminated by non-stationary and frequent artefacts. A plethora of noise reduction techniques have been developed, achieving remarkable performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!