Innovative techniques: a novel technique for intraoperative estimation of breast implant size in aesthetic and reconstructive breast surgery.

Aesthetic Plast Surg

St. Andrew's Centre for Burns and Plastic Surgery, Broomfield Hospital, Chelmsford, Essex CM1 7ET, UK.

Published: January 2008

The estimation of breast implant size in both aesthetic and reconstructive surgery often is a matter of clinical and intraoperative trial and error, with subsequent differences in the resulting postoperative outcomes. Numerous techniques for preoperative estimation of implant size are in current use. However, although such techniques are inexpensive, they often are inaccurate and prone to error on the part of both the surgeon and the patient. Techniques for intraoperative estimation of breast implant size involve either the use of trial sizers or the surgeon's own guesswork based on the preoperative consultation. A novel technique is presented that uses commonly available surgical gauze swabs. The senior author has applied this technique in both aesthetic and reconstructive breast surgery for many years. This easily reproducible method is inexpensive and produces reliable and highly satisfactory results.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00266-007-9045-2DOI Listing

Publication Analysis

Top Keywords

implant size
16
estimation breast
12
breast implant
12
aesthetic reconstructive
12
novel technique
8
intraoperative estimation
8
size aesthetic
8
reconstructive breast
8
breast surgery
8
breast
5

Similar Publications

Purpose: Cochlear implants (CI) are the most successful bioprosthesis in medicine probably due to the tonotopic anatomy of the auditory pathway and of course the brain plasticity. Correct placement of the CI arrays, respecting the inner ear anatomy are therefore important. The ideal trajectory to insert a cochlear implant array is defined by an entrance through the round window membrane and continues as long as possible parallel to the basal turn of the cochlea.

View Article and Find Full Text PDF

The effect of the foreign body response on drug elution from subdermal delivery systems.

Biomaterials

January 2025

Department of Nanomedicine, Houston Methodist Research Institute, Houston, TX, USA; Department of Surgery, Houston Methodist Hospital, Houston, TX, USA; Department of Radiation Oncology, Houston Methodist Hospital, Houston, TX, USA. Electronic address:

Contrasting findings are presented in the literature regarding the influence of foreign body response (FBR) on drug release from implantable drug delivery systems. To this end, here we sought direct evidence of the effect of the fibrotic tissue on subcutaneous drug release from long-acting drug delivery implants. Specifically, we investigated the pharmacokinetic impact of fibrotic encapsulation on a small molecule drug, islatravir (293 Da), and a large protein, IgG (150 kDa), administered via biocompatible implants.

View Article and Find Full Text PDF

Background: The purpose of this study was to assess impingement-free internal rotation (IR) in a virtual reverse shoulder arthroplasty simulation using a Statistical Shape Model based on scapula size.

Methods: A database of over 10,000 scapulae utilized for preoperative planning for shoulder arthroplasty was analyzed with a Statistical Shape Model to obtain 5 scapula sizes including the mean and 2 standard deviations. For each scapula model, one glenosphere size (33-42 mm) was selected as the best fit based on consensus among 3 shoulder surgeons.

View Article and Find Full Text PDF

Introduction: Repairing damaged cartilage poses significant challenges, particularly in cases of congenital cartilage defects such as microtia or congenital tracheal stenosis, or as a consequence of traumatic injury, as the regenerative potential of cartilage is inherently limited. Stem cell therapy and tissue engineering offer promising approaches to overcome these limitations in cartilage healing. However, the challenge lies in the size of cartilage-containing organs, which necessitates a large quantity of cells to fill the damaged areas.

View Article and Find Full Text PDF

Tapered Submerged Implants in an Augmented Posterior Maxilla After Oroantral Fistula Closure.

J Craniofac Surg

November 2024

Department of Oral and Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Korea.

Dental implantation in the posterior maxilla is challenging due to anatomic proximity to the sinuses, relative bone quality, and pre-existing sinus diseases. An oroantral fistula (OAF) acts as a pathologic pathway of bacteria and can cause sinus infections and complicate dental implant management. Bony augmentation between the sinus floor mucosa and the oral mucosa at the OAF closure site is another critical consideration.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!