Objective: We sought to evaluate the value of real-time 3-dimensional (3D) echocardiography (RT-3DE) in the pathologic morphology of complex congenital heart disease (CHD) using receiver operating characteristic (ROC) analysis.

Methods: Thirty patients with complex CHD were examined by 2-dimensional echocardiography (2DE) and RT-3DE. Their diagnoses of pathologic morphology were made by 3 echocardiographers blinded to clinical data. Their value was evaluated by ROC analysis using a 5-point categorical scale in major cardiovascular structures and spatial relationships among complex CHD.

Results: Compared with surgical findings, there were 75.6% of the definitely correct in RT-3DE and 64.4% in 2DE. ROC curve for RT-3DE was located left-superior to that for 2DE, and the area under ROC curve for RT-3DE (A = 0.96) was higher than that for 2DE (A = 0.90). There was significant difference between them by the method of Z test (Z = 2.64, P = .0083).

Conclusions: With the spatial 3D display of cardiovascular structural malformations, RT-3DE, coupled with conventional Doppler 2DE, may add information on complex CHD.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.echo.2007.08.040DOI Listing

Publication Analysis

Top Keywords

real-time 3-dimensional
8
3-dimensional echocardiography
8
complex congenital
8
congenital heart
8
heart disease
8
receiver operating
8
operating characteristic
8
pathologic morphology
8
complex chd
8
roc curve
8

Similar Publications

Free-Breathing Respiratory Triggered High-Pitch Lung CT: Insights From Phantom and Patient Scans.

Invest Radiol

January 2025

From the Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany (A. Schwarz, A. Simon, A.M.); Siemens Healthineers AG, Forchheim, Germany (A. Schwarz, C.H., J.D., A. Simon); Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany (F.K.W., S.G., M.S.); and Institut for Radiology, Pediatric and Neuroradiology, Helios Hospital, Schwerin, Germany (H.-J.R.).

Objective: Respiratory motion can affect image quality and thus affect the diagnostic accuracy of CT images by masking or mimicking relevant lung pathologies. CT examinations are often performed during deep inspiration and breath-hold to achieve optimal image quality. However, this can be challenging for certain patient groups, such as children, the elderly, or sedated patients.

View Article and Find Full Text PDF

RNA Translocation through Protein Nanopores: Interlude of the Molten RNA Globule.

J Am Chem Soc

January 2025

Department of Polymer Science and Engineering, University of Massachusetts, Amherst, Massachusetts 01003, United States.

Direct translocation of RNA with secondary structures using single-molecule electrophoresis through protein nanopores shows significant fluctuations in the measured ionic current, in contrast to unstructured single-stranded RNA or DNA. We developed a multiscale model combining the oxRNA model for RNA with the 3-dimensional Poisson-Nernst-Planck formalism for electric fields within protein pores, aiming to map RNA conformations to ionic currents as RNA translocates through three protein nanopores: α-hemolysin, CsgG, and MspA. Our findings reveal three distinct stages of translocation (pseudoknot, melting, and molten globule) based on contact maps and current values.

View Article and Find Full Text PDF

Background: Left ventricular (LV) volumes can be calculated from various linear, monoplane, and multiplane echocardiographic methods, and the same method can be applied to different imaging views. However, these methods and their variations have not been comprehensively evaluated against real-time 3-dimensional echocardiography (RT3D).

Hypothesis/objectives: To identify the LV volumetric approaches that produce the least bias and the best agreement with RT3D, and to assess interoperator reproducibility between an experienced and an inexperienced operator.

View Article and Find Full Text PDF

Objective: To validate the use of neural radiance fields (NeRF), a state-of-the-art computer vision technique, for rapid, high-fidelity 3-dimensional (3D) reconstruction in endoscopic sinus surgery (ESS).

Study Design: An experimental cadaveric pilot study.

Setting: Academic medical center.

View Article and Find Full Text PDF

Background: Perioperative right ventricular (RV) dysfunction is associated with increased morbidity and mortality in cardiac surgery patients. This study aimed to demonstrate proof of concept in generating intraoperative RV pressure-volume (PV) loops and conducting an end-systolic PV relationship (ESPVR) analysis using data obtained from routinely used intraoperative monitors.

Methods: Adult patients undergoing cardiac surgery with the placement of a pulmonary artery catheter (PAC) between May 2023 and March 2024 were included prospectively.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!