A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Drug-eluting stent for recurrent mesenteric artery in-stent restenosis. | LitMetric

Drug-eluting stent for recurrent mesenteric artery in-stent restenosis.

J Endovasc Ther

Cardiovascular Diagnosis and Endoluminal Interventions Unit, Rovigo General Hospital, Rovigo, Italy.

Published: October 2007

Purpose: To report the use of a drug-eluting stent (DES) for treatment of symptomatic in-stent restenosis (ISR) in the superior mesenteric artery (SMA).

Case Report: A 79-year-old woman suffering from chronic renal failure and needing dialysis was admitted for vomiting, postprandial abdominal pain, and weight loss for 3 months. Computed tomographic angiography (CTA) documented massive calcification of the vascular bed, mainly in the aorta, and a very tight ostial stenosis of the SMA. A 4.5-x20-mm Genesis stent was deployed at the ostium, with good angiographic result and immediate symptomatic benefit. After 3 months, symptoms recurred; angiography demonstrated ISR. Percutaneous angioplasty with a 4-x15-mm cutting balloon was performed. The patient remained asymptomatic for only 2 months; recurrent ISR at this time was treated with a 3.5-x24-mm coronary TAXUS Express paclitaxel-eluting coronary stent deployed inside the previously implanted stent. Under prolonged double antiplatelet regimen, the patient was asymptomatic at the 8-month follow-up; CTA demonstrated patency of the SMA.

Conclusion: Considering the high rate of restenosis and the periprocedural complications described with endovascular treatment of SMA stenosis, a drug-eluting stent may be a good option not only for the treatment of restenosis but also in de novo lesions, at least when the vessel diameter is <4.5 mm.

Download full-text PDF

Source
http://dx.doi.org/10.1177/152660280701400522DOI Listing

Publication Analysis

Top Keywords

drug-eluting stent
12
mesenteric artery
8
in-stent restenosis
8
stent deployed
8
stent
5
stent recurrent
4
recurrent mesenteric
4
artery in-stent
4
restenosis
4
restenosis purpose
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!