Inadvertent postdialysis anticoagulation due to heparin line locks.

Hemodial Int

Department of Renal Medicine, West London Renal and Transplant Centre, Hammersmith Hospital, London, UK.

Published: October 2007

Large-bore dual lumen in-dwelling venous catheters are used in hemodialysis. These catheters are usually locked with heparin after the treatment. This study addressed the underappreciated postdialysis coagulopathy that can result. Thirty-six patients were included: 7 dialyzed through arterio-venous fistulae, 29 through in-dwelling venous catheters. The latter group was further subdivided according to whether they received heparin or heparin-free dialysis. To assess the heparin lock, a full-dose heparin lock as well as a much weaker heparin lock and a citrate lock were used. To assess the coagulopathy, blood was taken 1 hr after dialysis. The activated partial thromboplastin time (APTT) and anti-Xa level was measured. Additionally, 6 venous catheters were removed and the amount of fluid expelled upon locking with saline was measured. Clotting from the patient group with arterio-venous fistulae was normal following dialysis. The patients with in-dwelling venous catheters and heparin locks had significantly deranged clotting; 6 out of 10 patients had abnormal APTT results. All patients with catheters, heparin-free dialysis, and heparin locks had deranged clotting (7 out of 7). The rate decreased significantly when heparinized saline was used as a lock. A subset of patients had a citrate lock rather than a heparin lock; the clotting results normalized in all but one patient. An in vitro study demonstrated immediate leakage of fluid from the end of the ports upon locking. Significant postdialysis anticoagulation can occur after dialysis, which can be attributed to the heparin line locks. This risk is considerably reduced when a citrate lock is used instead.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1542-4758.2007.00213.xDOI Listing

Publication Analysis

Top Keywords

heparin locks
16
venous catheters
16
heparin lock
16
in-dwelling venous
12
citrate lock
12
heparin
10
postdialysis anticoagulation
8
arterio-venous fistulae
8
heparin-free dialysis
8
lock
8

Similar Publications

Background: Patients in many underserved geographies lack access to invasive coronary angiography (ICA).

Objectives: This preclinical study explored the feasibility of telerobotic ICA between separate continents.

Methods: Using a novel robotic system, attempts were made to navigate a magnetic guidewire and diagnostic catheter from the aortic arch into a target coronary artery ostium in a fluid-filled cardiac model.

View Article and Find Full Text PDF

Safety of accessing brachial veins for large-bore upper extremity venous thrombectomy using ClotTriever Thrombectomy System.

CVIR Endovasc

January 2025

Department of Radiology, Section of Vascular and Interventional Radiology, University of Washington, 1959 Northeast Pacific Street, Seattle, WA, 98195, USA.

Purpose: To evaluate access site adverse events following ClotTriever-mediated large-bore mechanical thrombectomy via small upper extremity deep veins (< 6-mm).

Materials And Methods: Twenty patients, including 24 upper extremity venous access sites, underwent ClotTriever-mediated large-bore thrombectomy of the upper extremity and thoracic central veins for symptomatic deep vein obstruction unresponsive to anticoagulation. Patients without follow-up venous duplex examinations (n = 3) were excluded.

View Article and Find Full Text PDF

Central venous catheter (CVC) cannulation can be accompanied by serious complications. The appearance of catheter-related infections is associated with high morbimortality. The aim of this study is to evaluate the incidences of colonization and central line-associated bloodstream infections (CLABSI) in short-term CVCs in the elective surgery setting, as well as to analyze the related risk factors.

View Article and Find Full Text PDF

Small-bore feeding tubes (SBFT) in vulnerable patients carry a risk of iatrogenic pneumothorax by misplacement into the lung. This institution noted a series of iatrogenic pneumothoraxes caused by the placement of these devices. A resident-led, multidisciplinary team developed a hospital guideline through a consensus-driven process.

View Article and Find Full Text PDF

Objective: To provide evidence for further reducing the incidence of central line-associated bloodstream infection (CLABSI) according to investigation of the prevention and control of CLABSI in intensive care unit (ICU) in Shandong Province.

Methods: The questionnaire was developed by experts from Shandong Critical Care Medical Quality Control Center, combining domestic and foreign guidelines, consensus and research. A convenient sampling method was used to recruit survey subjects online from October 11 to 31, 2023 in the province to investigate the management status of central venous catheter (CVC) in ICU units of secondary and above hospitals.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!