Digital and transvaginal ultrasound cervical assessment for prediction of successful labor induction.

Int J Gynaecol Obstet

Department of Obstetrics and Gynecology, Perinatology Unit, Eskisehir Osmangazi University School of Medicine, Eskisehir, Turkey.

Published: January 2008

Objective: To compare the values of preinduction transvaginal cervical length measurements and Bishop score to predict successful labor induction.

Methods: A prospective, observational trial of nulliparous women undergoing labor induction. Inclusion criteria were gestational age between 36 and 42 weeks, singleton cephalic presentation of the fetus, and intact membranes. Preinduction cervical ripening was performed using 25 microg intravaginal misoprostol (PGE1), repeated every 4 h, up to a maximum of 3 doses. Induction was subsequently continued by oxytocin and amniotomy.

Results: A total of 43 women met the inclusion criteria. Mean preinduction cervical length for women with successful or failed labor induction was 26 mm (95% Confidence interval [CI], 27-32) and 34 mm (95% CI, 33-38), respectively (P=0.002). Mean Bishop scores for successful and failed induction groups were 5.4 (95% CI, 5.2-6.2) and 3.1 (95% CI, 2.8-3.5), respectively (P=0.003).

Conclusion: Digital examination and transvaginal ultrasound of the cervix predict successful labor induction with reasonable accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijgo.2007.07.014DOI Listing

Publication Analysis

Top Keywords

labor induction
16
successful labor
12
transvaginal ultrasound
8
cervical length
8
predict successful
8
inclusion criteria
8
preinduction cervical
8
successful failed
8
induction
6
successful
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!