A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Accuracy of cone-beam computed tomography imaging of the temporomandibular joint: comparisons with panoramic radiology and linear tomography. | LitMetric

Introduction: Cone-beam computed tomography (CBCT) is increasingly being used as an imaging modality, particularly in the assessment of the temporomandibular joint (TMJ). A blinded observational cross-sectional in-vitro study was conducted to compare the diagnostic accuracy of observers viewing images made with CBCT, panoramic radiography, and linear tomography. The task was to detect cortical erosions affecting the mandibular condylar head.

Methods: The sample consisted of 37 TMJ articulations from 30 skulls with either normal condylar morphology (n = 19) or erosion of the lateral pole (n = 18). The articulations were imaged by using corrected angle linear tomography (TOMO), normal (Pan-N) and TMJ-specific (Pan-TM) panoramic radiography, and CBCT. Digital images were obtained with photostimulable phosphor plates for all modalities except CBCT. The CBCT detector used an amorphous silicon flat-panel array combined with cesium iodide. Images and 10 rereads were presented to 10 observers on a flat-panel display at a pixel-to-monitor ratio of 1:1. CBCT multi-planar images were presented both statically (CBCT-S) and interactively (CBCT-I). The observers were permitted to scroll through axial (0.4 mm) and para-sagittal (1 mm) sections and then independently rate their confidence about the presence or absence of cortical erosion. Intraobserver reliability was determined by weighted kappa and diagnostic accuracy by the fitted area under the ROC curve. Means were compared by using ANOVA (P < or =.05).

Results: Intraobserver reliability was moderate (0.57 +/- 0.22; range, 0.34-0.78). Pan-N (0.72 +/- 0.15), CBCT-I (0.65 +/- 0.21), and CBCT-S (0.65 +/- 0.17) reliability was significantly greater than TOMO (0.44 +/- 0.25). The diagnostic accuracy of CBCT-I (0.95 +/- 0.05) and CBCT-S (0.77 +/- 0.17) was significantly greater than all other modalities (Pan-N [0.64 +/- 0.11], Pan-TM [0.55 +/- 0.11], TOMO [0.58 +/- 0.15]). CBCT-I was also more accurate than CBCT-S, and Pan-N was more accurate than Pan-TM and TOMO.

Conclusions: CBCT images provide superior reliability and greater accuracy than TOMO and TMJ panoramic projections in the detection of condylar cortical erosion.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ajodo.2005.10.032DOI Listing

Publication Analysis

Top Keywords

linear tomography
12
diagnostic accuracy
12
+/-
10
cone-beam computed
8
computed tomography
8
temporomandibular joint
8
panoramic radiography
8
cortical erosion
8
intraobserver reliability
8
065 +/-
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!