The aim of this retrospective study was to assess clinical outcomes after segmental wire fixation and bone grafting for repair of pars defects in patients with multiple-level lumbar spondylolysis. Subjects were 7 patients (5 men and 2 women, mean age 26.7 y) with multiple-level lumbar spondylolysis treated by segmental wire fixation and bone grafting at one of our affiliated institutions between 1983 and 2004. Clinical outcomes were determined by comparing preoperative and postoperative Japanese Orthopaedic Association scores and Mancab criteria, and healing of pars defects was evaluated by radiographic and computed tomography study. The condition involved 2 levels in 5 cases and 3 levels in 2 cases. The mean postoperative follow-up period was 51.0 months. The mean Japanese Orthopaedic Association score improved significantly from 21.29 before surgery to 27.86 after surgery, and the recovery rate was 85.21%. An "excellent" result was achieved in 5 cases, a "good" result in 1 case and a "fair" result in 1 case according to the Macnab criteria. Postoperative radiographs revealed healing of all defects in 4 cases, healing of 3 out of 4 defects in 2 cases, and no healing of any defect in 1 case. Pseudoarthrosis was related to wire breakage, and patients who did not obtain complete healing were patients who did not fully comply with instructions to wear a lumbar corset or restrict activity postoperatively. Segmental wire fixation and bone grafting were shown to be effective for multiple-level lumbar spondylolysis.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BSD.0b013e3180335c1fDOI Listing

Publication Analysis

Top Keywords

segmental wire
16
wire fixation
16
fixation bone
16
bone grafting
16
lumbar spondylolysis
16
multiple-level lumbar
12
grafting repair
8
clinical outcomes
8
pars defects
8
japanese orthopaedic
8

Similar Publications

Purpose: To theoretically and experimentally study implant lead tip heating caused by radiofrequency (RF) power deposition in different wire configurations that contain loop(s).

Methods: Maximum temperature rise caused by RF heating was measured at 1.5T on 20 insulated, capped wires with various loop and straight segment configurations.

View Article and Find Full Text PDF

How do lesions affect limb lengthening in children with Ollier's disease?

BMC Musculoskelet Disord

January 2025

Department of Pediatric Orthopaedics, Children's Hospital of Fudan University, National Children's Medical Center, 399 Wanyuan Rd, Minhang District, Shanghai, 201102, China.

Purpose: Ollier's disease (multiple enchondromatosis) can cause severe lower limb length discrepancy and deformity in children. Osteotomy and limb lengthening with external fixation can correct the lower extremity deformity. There may be lesions in the osteotomy part (OP), and the internal fixation part of the external fixation(FP).

View Article and Find Full Text PDF

Intranasal Outer Cortex Splinting With a Kirschner Wire to Immobilize Reduced Buckle-out Segments in Nasal Fractures.

J Craniofac Surg

October 2024

Department of Plastic Surgery, Kyung Hee University Hospital, Kyung Hee University College of Medicine, Seoul, Republic of Korea.

High-velocity lateral impacts to the nose sometimes cause nasal buckle-out fractures with a trapdoor buckle-out segment displaced outwards. Prolonged immobilization of a reduced buckle-out segment at risk for outward redisplacement remains challenging. Here we introduce a novel method of intranasal outer cortex splinting with a Kirshner (K)-wire to reinforce the reduced state and prevent outward re-displacement of the buckle-out segment.

View Article and Find Full Text PDF

Effective drug delivery to the posterior segment of the eye remains a challenge owing to the limitations of conventional methods such as intravitreal injections, which are associated with significant side effects. This study explored the use of hollow microneedles (HMNs) for localized intrascleral drug delivery as a minimally invasive alternative. Stainless steel HMNs with bevel angles of 30°, 45°, 60°, and 75° were fabricated using wire electron discharge machining.

View Article and Find Full Text PDF

Foreign body (FB) aspiration in children is a common emergency. Traditionally, rigid bronchoscopy has been considered to be the mainstay for removal. However, in certain cases, flexible bronchoscopy can prove to be a better option and avoid thoracic surgery and unnecessary morbidity.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!