Background/purpose: This study was performed to evaluate the role of non-contrast 3D time-of-flight (TOF) magnetic resonance angiography (MRA) to detect and quantify intracranial steno-occlusive disease.
Methods: Between April 2004 and January 2006, 45 patients with both 1.5T TOF MRA and digital subtraction angiography (DSA) performed within a 30-day interval were included. We evaluated the following intracranial arterial segments: petrous internal carotid artery (ICA), cavernous ICA, supraclinoid ICA, M1 of middle cerebral artery, A1 of anterior cerebral artery, P1 of posterior cerebral artery, basilar artery, and distal vertebral artery. In total, 675 arterial segments were evaluated and categorized as negative, moderate-1 (3049% stenosis), moderate-2 (5069%), severe (7099% stenosis, including gap sign on MRA), and occlusion.
Results: The sensitivity and specificity of TOF MRA for > 29% stenosis and > 49% stenosis were 94%, 96% and 95%, 96%, respectively; while sensitivity and specificity for occlusion lesions were both 100%. However, 44 segments (37% of diseased segments) were overestimated by MRA, including 20 false-positive stenoses (which occurred in 10 [22%] patients) and 24 overestimated stenosis degree. The gap sign as severe stenosis only showed about 21% sensitivity and 41% specificity. Seven lesions were underestimated by MRA: three arterial segments were out of the field of MRA examination, and four were moderate-1stenosis on DSA.
Conclusion: TOF MRA has high sensitivity and specificity in detecting all categories of stenosis degree and occlusion. However, it tends to overestimate lesions. Therefore, MRA can be considered as a screening study. Confirmation with other studies is recommended in doubtful cases.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S0929-6646(08)60030-3 | DOI Listing |
J Magn Reson Imaging
January 2025
Department of Radiology, Endeavor Health, Evanston, Illinois, USA.
Background: Luminal and hemodynamic evaluations of the cervical arteries inform the diagnosis and management of patients with cervical arterial disease.
Purpose: To demonstrate a 3D nonenhanced quantitative quiescent interval slice-selective (qQISS) magnetic resonance angiographic (MRA) strategy that provides simultaneous hemodynamic and luminal evaluation of the cervical arteries.
Study Type: Prospective.
J Magn Reson Imaging
January 2025
Department of Radiology, the First Medical Center, Chinese PLA General Hospital, Beijing, China.
Background: Middle cerebral artery (MCA) stenosis affects lenticulostriate arteries (LSAs) that supply the basal ganglia. Increased spatial resolution and signal-to-noise ratio of 7 T could facilitate morphological imaging of very-small-diameter LSAs.
Purpose: To evaluate differences in morphological characteristics of LSA among different MCA stenoses.
Sci Rep
December 2024
Department of Applied Mathematics, Technical Medical Centre, University of Twente, Enschede, The Netherlands.
The circle of Willis (CoW) is a circular arrangement of arteries in the human brain, exhibiting significant anatomical variability. The CoW is extensively studied in relation to neurovascular pathologies, with certain anatomical variants previously linked to ischemic stroke and intracranial aneurysms. In an individual CoW, arteries might be absent (aplasia) or underdeveloped (hypoplasia, diameter < 1 mm).
View Article and Find Full Text PDFQuant Imaging Med Surg
December 2024
Department of Radiology and Nuclear Medicine, Xuanwu Hospital, Capital Medical University, Beijing, China.
Background: Preliminary small-sample studies suggest that silent magnetic resonance angiography (MRA) has an advantage over time-of-flight MRA (TOF MRA) in the characterization of brain arteriovenous malformation (BAVM), but did not examine whether the imaging performance of silent MRA was affected by the intrinsic features of BAVM or common clinical factors. This study sought to compare silent MRA and TOF MRA in terms of the visualization and grading of BAVMs in various clinical settings.
Methods: In total, 85 participants (50 males, 35 females; mean age: 33.
Cureus
November 2024
Radiodiagnosis, Sawai Man Singh (SMS) Medical College and Hospital, Jaipur, IND.
Background: Stroke is a leading cause of death and disability worldwide, affecting millions annually. Accurate etiological diagnosis is critical for the effective treatment and prevention of recurrent strokes. Traditional luminal imaging techniques like computed tomography (CT) and magnetic resonance angiography (MRA) provide limited information, focusing solely on vessel lumen characteristics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!