Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: The Kirschner wire (K-wire) technique for fixation of rib cartilage grafts to the maxilla is a powerful tool in rhinoplasty. It gives the nose unparalleled anterior projection. However, the technique is challenging because of poor maxillary visualization through the open rhinoplasty approach. Inaccurate K-wire placement can cause dental injury or violation of the nasal/palatal mucosa. This study evaluates the efficacy of a surgical navigation system to guide K-wire placement.
Study Design: K-wires were placed, through an open rhinoplasty approach, into the maxilla of 12 fresh cadaver heads by a single surgeon. Six control specimens had K-wires placed without navigation. Six treatment specimens had K-wires placed with the "look-ahead navigation method," in which a surgical navigation device was attached to the K-wire gun. All maxillae were then sectioned to determine the final location of the K-wires.
Results: Four out of five (80%) of the K-wires were successfully placed in the treatment group, although only 3 out of 6 (50%) of the K-wires were successfully placed in the control group. One treatment K-wire was dislodged during the sectioning process and had to be excluded. The average K-wire deviation in the axial plane was less for the treatment group (0.2 +/- 0.4 mm) than for the control group (1.8 +/- 1.5 mm; P < .05).
Conclusion: When surgical navigation is used in K-wired cartilage strut graft placement to maxilla, it can improve the accuracy of K-wire placement. This may result in reduced complications due to errant K-wire placement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.tripleo.2007.06.017 | DOI Listing |