Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
A specific and sensitive method based on liquid chromatography-tandem mass spectrometry using atmospheric pressure chemical ionization (LC-APCI-MS/MS) has been developed for the determination of four anabolic steroids [trenbolone, methylboldenone, methyltestosterone, and norethandrolone] in bovine muscle. Methyltestosterone- d 3 was used as internal standard. The procedure involved enzymatic hydrolysis, extraction with tert-butyl methyl ether, defattening, and final cleanup with solid-phase extraction with Oasis HLB cartridges. The analytes were analyzed by reversed-phase LC-MS/MS, acquiring two diagnostic product ions from the chosen precursor [M + H] (+) for the unambiguous confirmation of hormones. The method was validated according to the European Commission Decision 2002/657/EC for the detection and confirmation of residues in products of animal origin. The limits of detection (LOD) and limits of quantitation (LOQ) were found to be 0.3 ng/g and 1.0 ng/g, respectively. The accuracy and precision have been determined, with recoveries ranging from 83% to 104% and the CV factor not exceeding the value of 7%. The decision limits CCalpha were calculated and ranged from 0.05 to 0.15 ng/g while the detection capabilities CCbeta ranged from 0.09 to 0.25 ng/g. The method proved to be sensitive and reliable and thus renders an appropriate means for residue analysis studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/jf0713455 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!