Object: The purpose of this study was to evaluate the accuracy of ventriculostomy catheter placement on a head- and hand-tracked high-resolution and high-performance virtual reality and haptic technology workstation.

Methods: Seventy-eight fellows and residents performed simulated ventriculostomy catheter placement on an ImmersiveTouch system. The virtual catheter was placed into a virtual patient's head derived from a computed tomography data set. Participants were allowed one attempt each. The distance from the tip of the catheter to the Monro foramen was measured.

Results: The mean distance (+/- standard deviation) from the final position of the catheter tip to the Monro foramen was 16.09 mm (+/- 7.85 mm).

Conclusions: The accuracy of virtual ventriculostomy catheter placement achieved by participants using the simulator is comparable to the accuracy reported in a recent retrospective evaluation of free-hand ventriculostomy placements in which the mean distance from the catheter tip to the Monro foramen was 16 mm (+/- 9.6 mm).

Download full-text PDF

Source
http://dx.doi.org/10.3171/JNS-07/09/0515DOI Listing

Publication Analysis

Top Keywords

ventriculostomy catheter
16
catheter placement
16
catheter monro
12
monro foramen
12
accuracy ventriculostomy
8
catheter
8
placement head-
8
head- hand-tracked
8
hand-tracked high-resolution
8
virtual reality
8

Similar Publications

Background: External ventricular drains (EVDs) provide an invaluable diagnostic method for accessing cerebrospinal fluid and therapeutically treating elevated intracranial pressure. Although complications including hemorrhage and infection have been well documented, the formation of iatrogenic pseudoaneurysms following EVD placement has rarely been reported. The authors present a case of this exceedingly rare complication of iatrogenic pseudoaneurysm formation following EVD placement.

View Article and Find Full Text PDF

Global disparities in neurosurgical care necessitate innovations addressing affordability and accuracy, particularly for critical procedures like ventriculostomy. This intervention, vital for managing life-threatening intracranial pressure increases, is associated with catheter misplacement rates exceeding 30% when using a freehand technique. Such misplacements hold severe consequences including haemorrhage, infection, prolonged hospital stays, and even morbidity and mortality.

View Article and Find Full Text PDF

Postoperative fever following neuroendoscopic procedures has been well-documented, yet specific differentiation based on the nature and site of the procedure remains lacking. Given the anatomical involvement of the hypothalamus in temperature regulation, we propose that endoscopic third ventriculostomy (ETV) may have a distinct impact on postoperative fever. This study aims to investigate this phenomenon.

View Article and Find Full Text PDF

Objective: Intraventricular hemorrhage (IVH) is a serious condition with high mortality rates and poor functional outcome in survivors. Treatment includes external ventricular drains (EVDs), which are associated with several complications. This study reports the clinical outcome and complication rate in patients with primary IVH (pIVH) and secondary IVH treated with EVDs.

View Article and Find Full Text PDF

This study aimed to develop and validate a cost-effective, customizable patient-specific phantom for simulating external ventricular drain placement, combining image segmentation, 3-D printing and molding techniques. Two variations of the phantom were created based on patient MRI data, integrating a realistic skin layer with anatomical landmarks, a 3-D printed skull, an agarose polysaccharide gel brain, and a ventricular cavity. To validate the phantom, 15 neurosurgeons, residents, and physician assistants performed 30 EVD placements.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!