Although drug-eluting stents reduce restenosis and target lesion revascularization compared with bare metal stents (BMSs), the specter of late stent thrombosis has curbed enthusiasm for the widespread use of drug-eluting stents. Alternatively, increasing BMS use would increase restenosis and potentially increase adverse events. The presentation and outcomes of BMS restenosis are controversial. We evaluated 2,539 patients with BMS restenosis referred for repeat revascularization. Major adverse cardiac events, including mortality and myocardial infarction (MI), were assessed at clinical presentation, 30 days, and 6 months. Patients with acute presentation (i.e., unstable angina requiring hospitalization or MI) were compared with patients with stable presentation. At presentation, 19.2% of patients were asymptomatic, 27.5% had exertional angina, 46.6% had unstable angina, and 6.7% had MI. Mortality and MI rates were 1.1% and 1.4%, respectively, at 30 days and 3.3% and 4.5%, respectively, at 6 months. Patients with acute coronary syndrome (ACS) and those without ACS had similarly low mortality rates at 30 days (1.2% ACS vs 1.0% non-ACS, p = 0.65) and 6 months (3.4% ACS vs 3.3% non-ACS, p = 0.93) and MI rates at 30 days (1.3% ACS vs 1.4% non-ACS, p = 0.87) and 6 months (4.7% ACS vs 4.3% non-ACS, p = 0.65). Combined major adverse cardiac events were similar at 30 days (2.5% vs 2.1%, p = 0.53) and 6 months (7.4% ACS vs 6.9%, non-ACS, p = 0.65). In conclusion, although BMS restenosis often manifests as an ACS, it is associated with a low incidence of 6-month major adverse cardiac events and does not predict a negative outcome.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjcard.2007.05.033DOI Listing

Publication Analysis

Top Keywords

bms restenosis
12
major adverse
12
adverse cardiac
12
cardiac events
12
non-acs 065
12
myocardial infarction
8
drug-eluting stents
8
months patients
8
patients acute
8
unstable angina
8

Similar Publications

Percutaneous Coronary Intervention (PCI) is a treatment method that involves reopening narrowed arteries with a balloon catheter that delivers a cylindrical, mesh-shaped implant device to the site of the stenosis. Currently, by applying a coating to a bare metal stent (BMS) surface to improve biocompatibility, the main risks after PCI, such as restenosis and thrombosis, are reduced while maintaining the basic requirements for the mechanical behavior of the stent itself. In this work, for the first time, the development and optimization process of the spatial structure of the Co-Cr stent (L-605) with a graphene-based coating using cold-wall chemical vapor deposition (CW-CVD) to ensure uniform coverage of the implant was attempted.

View Article and Find Full Text PDF

Background: Coronary stenting operations have become the main option for the treatment of coronary heart disease. Vessel recovery after stenting has emerged as a critical factor in reducing possible complications. In this study, we evaluated the feasibility, safety and efficacy of locally administered intraluminal gene therapy delivered using a specialized infusion balloon catheter.

View Article and Find Full Text PDF

Background: Despite significant reductions in in-stent restenosis (ISR) incidence with the adoption of drug-eluting stents (DES) over bare metal stents (BMS), ISR remains an unresolved issue in the DES era. The risk factors associated with DES-ISR have not been thoroughly analyzed. This meta-analysis aims to identify the key factors and quantify their impact on DES-ISR.

View Article and Find Full Text PDF

Background: In-stent restenosis (ISR) is the primary cause of stroke recurrence after intracranial stenting. Drug-eluting stents (DES) have recently shown great potential for reducing restenosis. This systematic review aimed to evaluate the efficacy and safety of DES compared with bare-metal stents (BMS) for intracranial atherosclerotic stenosis (ICAS).

View Article and Find Full Text PDF

Background: In-stent restenosis (ISR) is a crucial factor that affects the long-term efficacy of intracranial bare metal stent (BMS) implantation for intracranial atherosclerotic stenosis (ICAS). Patients with intracranial ISR are at a high risk of recurrent ischaemic events. The NOVA intracranial drug-eluting stent (DES) trial demonstrates that a DES can reduce ISR and stroke recurrence after intracranial bare stent implantation.

View Article and Find Full Text PDF