A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Targeting device for intramedullary nails: a new high-stable mechanical guide. | LitMetric

Targeting device for intramedullary nails: a new high-stable mechanical guide.

Injury

Orthopaedic and Trauma Department, Hôpital du Chablais, Monthey, Switzerland.

Published: February 2008

One of the most demanding steps of an intramedullary nailing is the distal locking. The aim of this study is to evaluate clinically and prospectively a new targeting guide. Twenty-five patients were treated consecutively in two different trauma centres (level one and one general hospital) by two different surgeons who were instructed on using the new device. Reduction of the fracture, intramedullary nailing and proximal locking are performed according to standard procedures. Then the new targeting device is used for distal locking. Evaluations are focused on the time it takes to perform the distal locking, the duration of the irradiation exposure and the duration of the complete procedure. In terms of duration, our results are comparable to those reported in the literature but this new device has more advantages than any other system. This new device is fully mechanical and is solidly linked to the patient. It can be used with any existing radioscopic equipment in any hospital. The guide is manually adjustable out of the X-ray field avoiding the surgeon being irradiated. The procedure is easy to learn and reproducible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.injury.2007.06.006DOI Listing

Publication Analysis

Top Keywords

distal locking
12
targeting device
8
intramedullary nailing
8
device intramedullary
4
intramedullary nails
4
nails high-stable
4
high-stable mechanical
4
mechanical guide
4
guide demanding
4
demanding steps
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!