Unlabelled: The modern removable partial denture (RPD), in response to the increased esthetic demands of our patients, is no longer acceptable if it requires visible buccal and facial clasp arms for retention. By eliminating the bracing arm and having its functions taken by paralleled guide planes and precise, positive rests, the retentive element, a lingual circumferential wire clasp arm, will provide the same amount of retentive force as if it were placed on the buccal surface and will not be visible. Designs for the major connector either plate the lingual surface of the abutment or, as in a lingual bar, leave that surface open. Both of these situations are adaptable to the lingual retentive clasp and are illustrated in this article.

Clinical Significance: Design features such as metal clasps needed for the retention of RPDs can be very unsightly, creating an esthetic problem. This article reviews the concepts for creating lingual clasp arms that enhance the esthetic quality of prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1708-8240.2007.00112.xDOI Listing

Publication Analysis

Top Keywords

clasp arm
8
clasp arms
8
lingual
6
clasp
5
lingual retention
4
retention elimination
4
elimination visible
4
visible clasp
4
arm unlabelled
4
unlabelled modern
4

Similar Publications

Transcatheter Edge-to-Edge Repair in Patients With Complex Tricuspid Valve Anatomy.

JACC Cardiovasc Interv

December 2024

University of Virginia, Charlottesville, Virginia, USA. Electronic address: https://twitter.com/psorajja.

Article Synopsis
  • Untreated severe tricuspid regurgitation (TR) is linked to poor health outcomes, making effective treatment essential.
  • The study evaluated the 1-year results of transcatheter edge-to-edge repair (TEER) using the TriClip system in patients with complex tricuspid valve issues, finding significant improvements in patient survival and quality of life.
  • Results showed that 81% of patients experienced a reduction in TR to moderate or less after one year, with no major adverse effects noted in the first 30 days post-procedure.
View Article and Find Full Text PDF

The geometrical accuracy of additively manufactured pure titanium clasps depends on the building orientation. The aim of this study is to compare the geometrical accuracy and the fatigue lives predicted by finite element analysis (FEA) among three clasps manufactured with different building orientations. Besides, this paper proposed a calculation method of the moment of inertia of area and cross-sectional area along with the arm as the geometrical parameters.

View Article and Find Full Text PDF

Purpose: The purpose of this in vitro study was to evaluate the trueness of removable partial denture clasps fabricated with titanium (Ti) through the selective laser melting (SLM) technique compared to cobalt-chromium alloys (CoCr).

Materials And Methods: A virtual Aker clasp was designed on a scanned tooth, and SLM printers were used to print 20 claps using cobalt chromium (n = 10) and titanium alloy (n = 10). The deviation between the printed clasps and reference design was measured using the surface matching software (Geomagic control x) at rest, retentive tip, reciprocal tip, retentive shoulder, and reciprocal shoulder.

View Article and Find Full Text PDF

This in vitro study aimed to evaluate the additive manufacturing (AM) of cobalt chromium Co-Cr and titanium Ti alloy clasps for clinical use. After scanning the Ni-Cr die of the first molar, Akers' clasps were designed using computer-aided design/ computer-aided manufacturing (CAD/CAM). The clasps were manufactured from Co-Cr-W dental alloy and Ti-6Al-4V alloy powder using AM machines.

View Article and Find Full Text PDF

Retention and fatigue performance of modified polyetheretherketone clasps for removable prosthesis.

J Mech Behav Biomed Mater

June 2024

Department of Oral Special Consultation, The Affiliated Stomatological Hospital of Nanjing Medical University, Nanjing, PR China; State Key Laboratory Cultivation Base of Research, Prevention and Treatment for Oral Diseases (Nanjing Medical University), Nanjing, PR China; Jiangsu Province Engineering Research Center of Stomatological Translational Medicine, Nanjing, PR China. Electronic address:

Purpose: Polyetheretherketone (PEEK) is considered as an alternative to metal material for removable partial denture (RPD). However, the retentive force is not strong as a metal RPD. This study investigated the retention and fatigue performance of PEEK clasps with different proportions of clasp arm engaging the undercut to verify a new strategy to improve their clinical performance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!