We experienced differential lung ventilation using laryngeal mask airway (LMA) and a bronchial blocker tube for a patient with unanticipated difficult intubation. A 27-year-old man was diagnosed as the left spontaneous pneumothorax and scheduled for bulla excision with video-assisted thoracic surgery. Because of failure in tracheal intubation of the usual double lumen tube, we inserted LMAProseal #4 and accomplished differential lung ventilation using a bronchial blocker tube through LMA. This method will be effective in differential lung ventilation of the patient with difficult airway.

Download full-text PDF

Source

Publication Analysis

Top Keywords

lung ventilation
16
bronchial blocker
12
blocker tube
12
differential lung
12
ventilation laryngeal
8
laryngeal mask
8
mask airway
8
tube patient
8
patient unanticipated
8
unanticipated difficult
8

Similar Publications

Lung Clearance Index: A Sensitive Measure of Airway Function Improvement in Adolescents After Weight Loss from Bariatric Surgery.

Respir Med

January 2025

Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel; Clalit Health Services, Dan Petah Tikva District, Petah Tikva, Israel. Electronic address:

Background: Morbid obesity in adolescents impacts respiratory function, often leading to reduced lung volume and obstructive ventilatory defects. However, standard spirometric values frequently remain within normal ranges.

Objectives: We hypothesized that Lung Clearance Index (LCI) is a more sensitive marker for detecting airway dysfunction in adolescents with morbid obesity than conventional lung function tests.

View Article and Find Full Text PDF

Introduction And Importance: Severe aortic stenosis (AS) and chronic obstructive pulmonary disease (COPD) significantly increase perioperative morbidity and mortality. This case report discusses the challenges of managing a 75-year-old male patient with severe AS and advanced COPD undergoing elective abdominal aortic aneurysm (AAA) repair.

Case Presentation: The patient presented with a 6.

View Article and Find Full Text PDF

Objective: To determine the impact of prolonged storage of donor lungs at 10°C of up to 24h on outcome after lung transplantation.

Background: An increasing body of evidence suggests 10°C as the optimal storage temperature for donor lungs. A recent study showed that cold ischemic times can be safely expanded to >12h when lungs are stored at 10°C.

View Article and Find Full Text PDF

The purpose of this work is to evaluate the feasibility of lung imaging using 3D electrical impedance tomography (EIT) during spontaneous breathing trials (SBTs) in patients with acute hypoxic respiratory failure. EIT is a noninvasive, nonionizing, real-time functional imaging technique, suitable for bedside monitoring in critically ill patients. EIT data were collected in 24 mechanically ventilated patients immediately preceding and during a SBT on two rows of 16 electrodes using a simultaneous multicurrent source EIT system for 3D imaging.

View Article and Find Full Text PDF

Introduction: The factors influencing meconium aspiration syndrome (MAS) severity remain poorly understood. In a piglet model of MAS, we hypothesized the respiratory microbiome would reflect the bacterial signature of meconium with short-chain fatty acid (SCFA) accumulation as a byproduct of bacterial fermentation.

Methods: Cesarean section at approximately 115-day term was performed on two sows.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!