Signals from the brain could provide a non-muscular communication and control system, a brain-computer interface (BCI), for people who are severely paralyzed. A common BCI research strategy begins by decoding kinematic parameters from brain signals recorded during actual arm movement. It has been assumed that these parameters can be derived accurately only from signals recorded by intracortical microelectrodes, but the long-term stability of such electrodes is uncertain. The present study disproves this widespread assumption by showing in humans that kinematic parameters can also be decoded from signals recorded by subdural electrodes on the cortical surface (ECoG) with an accuracy comparable to that achieved in monkey studies using intracortical microelectrodes. A new ECoG feature labeled the local motor potential (LMP) provided the most information about movement. Furthermore, features displayed cosine tuning that has previously been described only for signals recorded within the brain. These results suggest that ECoG could be a more stable and less invasive alternative to intracortical electrodes for BCI systems, and could also prove useful in studies of motor function.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1741-2560/4/3/012DOI Listing

Publication Analysis

Top Keywords

signals recorded
16
kinematic parameters
8
intracortical microelectrodes
8
signals
6
decoding two-dimensional
4
two-dimensional movement
4
movement trajectories
4
trajectories electrocorticographic
4
electrocorticographic signals
4
signals humans
4

Similar Publications

Background: This study aimed to provide a comprehensive review of adverse events (AEs) associated with factor Xa (FXa) inhibitors in pediatric patients.

Methods: We searched PubMed, Embase, Cochrane Library, ClinicalTrials.gov, and the European Union Clinical Trials Register for English-language records from the establishment of the database up to October 17, 2023.

View Article and Find Full Text PDF

SCN10A gene polymorphism is associated with pain sensitivity and postoperative analgesic effects in patients undergoing gynecological laparoscopy.

Eur J Med Res

January 2025

Department of Anesthesiology, Chongqing Health Center for Women and Children, Women and Children's Hospital of Chongqing Medical University, No. 120, Longshan Road, Yubei District, Chongqing, 401147, China.

Background: Postoperative pain intensity is influenced by various factors, including genetic variations. The SCN10A gene encodes the Nav1.8 sodium channel protein, which is crucial for pain signal transmission in peripheral sensory neurons.

View Article and Find Full Text PDF

Spontaneous otoacoustic emission as a novel method to screen pulsatile tinnitus caused by sigmoid sinus wall abnormalities: a prospective study.

Eur Arch Otorhinolaryngol

January 2025

ENT Institute and Department of Otorhinolaryngology, Eye & ENT Hospital, Fudan University, Shanghai, 200031, China.

Objective: To evaluate the diagnostic potential of spontaneous otoacoustic emissions (SOAE), distortion product otoacoustic emissions (DPOAE), and pure-tone audiometry (PTA) in patients with pulsatile tinnitus (PT) caused by sigmoid sinus wall anomalies (SSWA).

Methods: This study included 20 PT patients and 20 matched healthy controls. SOAE, DPOAE, and PTA were assessed before and after compression of the internal jugular vein.

View Article and Find Full Text PDF

Detection of epileptogenic zones in people with epilepsy using optimized EEG-fMRI.

Epilepsy Behav

January 2025

Department of Neurology, Neurological Institute, Taipei Veterans General Hospital, Taipei, Taiwan; College of Medicine, National Yang Ming Chiao Tung University, Taipei, Taiwan. Electronic address:

Purpose: Concurrent electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) have been used to assist in the presurgical localization of seizure foci in people with epilepsy. Our study aimed to examine the clinical feasibility of an optimized concurrent EEG-fMRI protocol.

Methods: The optimized protocol employed a fast-fMRI sequence (sampling rate = 10 Hz) with a spare arrangement, which allowed a time window of 1.

View Article and Find Full Text PDF

The cortical tracking of the acoustic envelope is a phenomenon where the brain's electrical activity, as recorded by electroencephalography (EEG) signals, fluctuates in accordance with changes in stimulus intensity (the acoustic envelope of the stimulus). Understanding speech in a noisy background is a key challenge for people with hearing impairments. Speech stimuli are therefore more ecologically valid than clicks, tone pips, or speech tokens (e.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!